Millin, Anthony E. - Abstract:
- Abstract: Background and purpose: Current automated radiotherapy planning solutions do not allow for the intuitive exploration of different treatment options during protocol calibration. This work introduces an automated planning solution, which aims to address this problem through incorporating Pareto navigation techniques into the calibration process. Materials and methods: For each tumour site a set of planning goals is defined. Utilising Pareto navigation techniques an operator calibrates the solution through intuitively exploring different treatment options: selecting the optimum balancing of competing planning goals for the given site. Once calibrated, fully automated plan generation is possible, with specific algorithms implemented to ensure trade-off balancing of new patients is consistent with that during calibration. Using the proposed methodology the system was calibrated for prostate and seminal vesicle treatments. The resultant solution was validated through quantitatively comparing the dose distribution of automatically generated plans (VMATAuto ) against the previous clinical plan, for ten randomly selected patients. Results: VMATAuto yielded statistically significant improvements in: PTV conformity indices, high dose bladder metrics, mean bowel dose, and the majority of rectum dose metrics. Of particular note was the reduction in mean rectum dose (median 25.1 Gy vs. 27.5 Gy), rectum V24.3Gy (median 41.1% vs. 46.4%), and improvement in the conformity index forAbstract: Background and purpose: Current automated radiotherapy planning solutions do not allow for the intuitive exploration of different treatment options during protocol calibration. This work introduces an automated planning solution, which aims to address this problem through incorporating Pareto navigation techniques into the calibration process. Materials and methods: For each tumour site a set of planning goals is defined. Utilising Pareto navigation techniques an operator calibrates the solution through intuitively exploring different treatment options: selecting the optimum balancing of competing planning goals for the given site. Once calibrated, fully automated plan generation is possible, with specific algorithms implemented to ensure trade-off balancing of new patients is consistent with that during calibration. Using the proposed methodology the system was calibrated for prostate and seminal vesicle treatments. The resultant solution was validated through quantitatively comparing the dose distribution of automatically generated plans (VMATAuto ) against the previous clinical plan, for ten randomly selected patients. Results: VMATAuto yielded statistically significant improvements in: PTV conformity indices, high dose bladder metrics, mean bowel dose, and the majority of rectum dose metrics. Of particular note was the reduction in mean rectum dose (median 25.1 Gy vs. 27.5 Gy), rectum V24.3Gy (median 41.1% vs. 46.4%), and improvement in the conformity index for the primary PTV (median 0.86 vs. 0.79). Dosimetric improvements were not at the cost of other dose metrics. Conclusions: An automated planning methodology with a Pareto navigation based calibration has been developed, which enables the complex balancing of competing trade-offs to be intuitively incorporated into automated protocols. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 10(2019)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 10(2019)
- Issue Display:
- Volume 10, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 10
- Issue:
- 2019
- Issue Sort Value:
- 2019-0010-2019-0000
- Page Start:
- 41
- Page End:
- 48
- Publication Date:
- 2019-04
- Subjects:
- Intensity modulated radiotherapy -- VMAT -- Treatment planning -- Automation -- Pareto navigation -- Prostate cancer -- Multicriteria optimization
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2019.04.005 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10934.xml