Intrarater reliability and agreement of a modified Closed Kinetic Chain Upper Extremity Stability Test. (July 2019)
- Record Type:
- Journal Article
- Title:
- Intrarater reliability and agreement of a modified Closed Kinetic Chain Upper Extremity Stability Test. (July 2019)
- Main Title:
- Intrarater reliability and agreement of a modified Closed Kinetic Chain Upper Extremity Stability Test
- Authors:
- Degot, Matthieu
Blache, Yoann
Vigne, Grégory
Juré, Dimitri
Borel, Florent
Neyton, Lionel
Rogowski, Isabelle - Abstract:
- Abstract: Objectives: To assess the reliability of a modified procedure for Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST). Design: Intra- and intersession reliability and agreement; Setting: Clinical. Participants: Twenty-seven asymptomatic athletes. Main outcome measures: The modifications (m-CKCUEST) in CKCUEST procedure consisted in hand spacing at one half arm-span, and to complete the three regular-series of 15 s exertion by performing a fourth 1-min series during which the number of touches was counted every 15 s. The intra- and intersession reliability and agreement were assessed for the numbers of touches in order to produce two outcome measures: m-CKCUEST score and muscular endurance index. Results: The most reliable m-CKCUEST score was obtained when averaging the numbers of touches of the second and third sets (Intraclass Coefficient of Correlation(3, k); ICC = 0.92). Good reliability was found for muscular endurance index computed when dividing the one-half number of touches counted during the last 30 s of 1-min set, by the m-CKCUEST score calculated above (ICC = 0.86). Conclusions: The m-CKCUEST allowed the production of two reliable outcome measures, which assessed the upper limb stability and the muscular endurance. Such outcomes may be used in a follow-up to assess performance or rehabilitation level. Highlights: Hand spacing and exertion duration were changed to perform CKCUEST. CKCUEST-score with modified-procedure met the criteria ofAbstract: Objectives: To assess the reliability of a modified procedure for Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST). Design: Intra- and intersession reliability and agreement; Setting: Clinical. Participants: Twenty-seven asymptomatic athletes. Main outcome measures: The modifications (m-CKCUEST) in CKCUEST procedure consisted in hand spacing at one half arm-span, and to complete the three regular-series of 15 s exertion by performing a fourth 1-min series during which the number of touches was counted every 15 s. The intra- and intersession reliability and agreement were assessed for the numbers of touches in order to produce two outcome measures: m-CKCUEST score and muscular endurance index. Results: The most reliable m-CKCUEST score was obtained when averaging the numbers of touches of the second and third sets (Intraclass Coefficient of Correlation(3, k); ICC = 0.92). Good reliability was found for muscular endurance index computed when dividing the one-half number of touches counted during the last 30 s of 1-min set, by the m-CKCUEST score calculated above (ICC = 0.86). Conclusions: The m-CKCUEST allowed the production of two reliable outcome measures, which assessed the upper limb stability and the muscular endurance. Such outcomes may be used in a follow-up to assess performance or rehabilitation level. Highlights: Hand spacing and exertion duration were changed to perform CKCUEST. CKCUEST-score with modified-procedure met the criteria of reliability. Muscular endurance index met the criteria of reliability. Both outcomes measures may be used in performance and rehabilitation assessment. … (more)
- Is Part Of:
- Physical therapy in sport. Volume 38(2019)
- Journal:
- Physical therapy in sport
- Issue:
- Volume 38(2019)
- Issue Display:
- Volume 38, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 2019
- Issue Sort Value:
- 2019-0038-2019-0000
- Page Start:
- 44
- Page End:
- 48
- Publication Date:
- 2019-07
- Subjects:
- Hand spacing -- CKCUEST -- Shoulder stability -- Muscular endurance index
Sports physical therapy -- Periodicals
Sports injuries -- Patients -- Rehabilitation -- Periodicals
Athletic Injuries -- diagnosis -- Periodicals
Athletic Injuries -- therapy -- Periodicals
Physical Therapy -- Periodicals
Sports Medicine -- Periodicals
615.82088796 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1466853X ↗
http://www.clinicalkey.com/dura/browse/journalIssue/1466853X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/1466853X ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journal ↗ - DOI:
- 10.1016/j.ptsp.2019.04.017 ↗
- Languages:
- English
- ISSNs:
- 1466-853X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6476.350650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10919.xml