Risk factors for stroke on left ventricular assist devices. Issue 6 (17th May 2018)
- Record Type:
- Journal Article
- Title:
- Risk factors for stroke on left ventricular assist devices. Issue 6 (17th May 2018)
- Main Title:
- Risk factors for stroke on left ventricular assist devices
- Authors:
- Bishawi, Muath
Joseph, Jeremy
Patel, Chetan
Schroder, Jacob
Daneshmand, Mani
Bowles, Dawn
Rogers, Joseph
Milano, Carmelo - Abstract:
- Abstract: Background: Patients with end‐stage heart failure on left ventricular assist devices (LVADs) are predisposed to a high incidence of stroke. Preoperative factors associated with increased stroke risk are poorly understood. Methods: We performed a single‐center retrospective review of all patients from 2009 to 2014 in whom a rotary flow LVAD was implanted. All patients with symptoms of a cerebrovascular event underwent a non‐contrast head computed tomography scan. Logistic regression was used to determine factors associated with stroke both on univariate and multivariable analysis. Results: A total of 390 patients were retrospectively analyzed and of those 61 (15.6%) had a stroke at an average follow‐up of 3.5 ± 1.6 years. The majority were male (72%) and were treated a priori as destination therapy (73%). The proportion of patient receiving a centrifugal flow pump was 23% compared to 77% receiving an axial flow pump. For those patients who experienced a stroke and then died, the average time from stroke to death was 158 ± 296 days. Of the 61 patients who had a stroke, 38 (62%) died ( P < 0.001 compared to death rate without a stroke). On Cox regression analysis, a history of cerebrovascular accident (CVA), hyperlipidemia, and history of venous thromboembolism (VTE) were independently associated with stroke while on LVAD support. Conclusion: Postoperative stroke after LVAD implantation was associated with higher mortality. A history of previous CVA, VTE, andAbstract: Background: Patients with end‐stage heart failure on left ventricular assist devices (LVADs) are predisposed to a high incidence of stroke. Preoperative factors associated with increased stroke risk are poorly understood. Methods: We performed a single‐center retrospective review of all patients from 2009 to 2014 in whom a rotary flow LVAD was implanted. All patients with symptoms of a cerebrovascular event underwent a non‐contrast head computed tomography scan. Logistic regression was used to determine factors associated with stroke both on univariate and multivariable analysis. Results: A total of 390 patients were retrospectively analyzed and of those 61 (15.6%) had a stroke at an average follow‐up of 3.5 ± 1.6 years. The majority were male (72%) and were treated a priori as destination therapy (73%). The proportion of patient receiving a centrifugal flow pump was 23% compared to 77% receiving an axial flow pump. For those patients who experienced a stroke and then died, the average time from stroke to death was 158 ± 296 days. Of the 61 patients who had a stroke, 38 (62%) died ( P < 0.001 compared to death rate without a stroke). On Cox regression analysis, a history of cerebrovascular accident (CVA), hyperlipidemia, and history of venous thromboembolism (VTE) were independently associated with stroke while on LVAD support. Conclusion: Postoperative stroke after LVAD implantation was associated with higher mortality. A history of previous CVA, VTE, and hyperlipidemia were independently associated with stroke while on LVAD support. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 33:Issue 6(2018)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 33:Issue 6(2018)
- Issue Display:
- Volume 33, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2018-0033-0006-0000
- Page Start:
- 348
- Page End:
- 352
- Publication Date:
- 2018-05-17
- Subjects:
- LVAD -- risk factors -- stroke
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.13718 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10908.xml