Compliance with wearing an abduction brace after arthroscopic rotator cuff repair: A prospective, sensor-controlled study. (August 2019)
- Record Type:
- Journal Article
- Title:
- Compliance with wearing an abduction brace after arthroscopic rotator cuff repair: A prospective, sensor-controlled study. (August 2019)
- Main Title:
- Compliance with wearing an abduction brace after arthroscopic rotator cuff repair: A prospective, sensor-controlled study
- Authors:
- Grubhofer, Florian
Gerber, Christian
Meyer, Dominik C
Wieser, Karl
Ernstbrunner, Lukas
Catanzaro, Sabrina
Bouaicha, Samy - Abstract:
- Background: Immobilization, using a shoulder abduction brace, may be important after rotator cuff repair to achieve successful tendon-to-bone healing. Compliance with wear time is a concern. Objectives: Therefore, the abduction brace wearing time was assessed with temperature-sensitive sensors to objectively measure the abduction brace wearing compliance rate. Study design: Level of evidence I, prospective observational study. Methods: A temperature sensor was implanted into 54 standard shoulder abduction braces, worn by 50 patients (27 women; mean age, 56 years). At 6 weeks post-surgery, patients reported the number of hours they had worn the brace. The patient-reported and sensor data were compared, and the compliance rate (relative to the recommended wearing time) was determined, with compliance being the primary end-point and the discrepancy between the measured and patient-reported wear time being the secondary end-point. Results: Compliance was ⩾80% in 24 (48%) patients. Sensor-based compliance was lower than self-reported compliance (75% versus 96%, p ⩽ 0.001). Compliance was not predicted by age, sex, smoking, educational, employment, living status, or handedness. Conclusions: Roughly 50% of patients did not wear the brace at least 80% of the recommended time. Self-reported compliance is significantly lower than sensor-based compliance. Compliance was not predicted by measured demographic variables. Clinical relevance: This is the first study in which the abductionBackground: Immobilization, using a shoulder abduction brace, may be important after rotator cuff repair to achieve successful tendon-to-bone healing. Compliance with wear time is a concern. Objectives: Therefore, the abduction brace wearing time was assessed with temperature-sensitive sensors to objectively measure the abduction brace wearing compliance rate. Study design: Level of evidence I, prospective observational study. Methods: A temperature sensor was implanted into 54 standard shoulder abduction braces, worn by 50 patients (27 women; mean age, 56 years). At 6 weeks post-surgery, patients reported the number of hours they had worn the brace. The patient-reported and sensor data were compared, and the compliance rate (relative to the recommended wearing time) was determined, with compliance being the primary end-point and the discrepancy between the measured and patient-reported wear time being the secondary end-point. Results: Compliance was ⩾80% in 24 (48%) patients. Sensor-based compliance was lower than self-reported compliance (75% versus 96%, p ⩽ 0.001). Compliance was not predicted by age, sex, smoking, educational, employment, living status, or handedness. Conclusions: Roughly 50% of patients did not wear the brace at least 80% of the recommended time. Self-reported compliance is significantly lower than sensor-based compliance. Compliance was not predicted by measured demographic variables. Clinical relevance: This is the first study in which the abduction brace adherence of patients after rotator cuff repair was assessed by the use of a temperature-sensitive sensor. The postoperative use of these braces is questionable as the patient's abduction brace adherence is low. The self-reported wearing compliance is unreliable. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 43:Number 4(2019)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 43:Number 4(2019)
- Issue Display:
- Volume 43, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2019-0043-0004-0000
- Page Start:
- 440
- Page End:
- 446
- Publication Date:
- 2019-08
- Subjects:
- Upper limb orthotics -- orthotics -- rehabilitation of orthoses users -- rehabilitation
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364619837794 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10911.xml