Comparison of two-view digital breast tomosynthesis to three-view digital mammography in a simulated screening setting. (September 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of two-view digital breast tomosynthesis to three-view digital mammography in a simulated screening setting. (September 2019)
- Main Title:
- Comparison of two-view digital breast tomosynthesis to three-view digital mammography in a simulated screening setting
- Authors:
- Kim, Yoon-Jin
Sechopoulos, Ioannis
Newell, Mary S
Ho, Christopher P
Holbrook, Anna I
Fleming, Margaret
Hamlin, Marae B
Handa, Priyanka
Braykov, Nikolay
D'Orsi, Carl J - Abstract:
- Background: Although digital breast tomosynthesis (DBT) may be an effective breast cancer screening modality, alternatives are important to explore as this technique presents some challenges for population screening implementation. Purpose: To compare the detection performance of three-view (craniocaudal [CC] + mediolateral oblique [MLO] + mediolateral/lateromedial [ML/LM]) digital mammography (DM) to two-view (CC + MLO) DBT. Material and Methods: In this institutional review board-approved study, recalled screening DBT exams from 3 March 2014 to 31 March 2015 with a ML/LM view acquired within 30 days were retrospectively reviewed for detection of breast cancer. Six radiologists blinded to outcomes evaluated two-view DBT, which included DM and tomosynthesis images, and three-view DM. Probability of malignancy and a BI-RADS score were assigned. Primary outcomes were area under the receiver operating characteristic curve (AUC) and benign and malignant recall rates. Results: The cohort included 121 cases: 37% were malignant and 63% were benign. Reader-averaged AUCs were 0.846 (95% confidence interval [CI] = 0.787–0.905) and 0.853 (95% CI = 0.802–0.904) for three-view DM and DBT, respectively. Benign and malignant recall rates were 53% and 74% for three-view DM and 52% and 75% for DBT, respectively. There was no difference in AUCs ( P = 0.692), and benign ( P = 1) and malignant ( P = 1) recall rates. Conclusion: In this retrospective initial study, the detection performanceBackground: Although digital breast tomosynthesis (DBT) may be an effective breast cancer screening modality, alternatives are important to explore as this technique presents some challenges for population screening implementation. Purpose: To compare the detection performance of three-view (craniocaudal [CC] + mediolateral oblique [MLO] + mediolateral/lateromedial [ML/LM]) digital mammography (DM) to two-view (CC + MLO) DBT. Material and Methods: In this institutional review board-approved study, recalled screening DBT exams from 3 March 2014 to 31 March 2015 with a ML/LM view acquired within 30 days were retrospectively reviewed for detection of breast cancer. Six radiologists blinded to outcomes evaluated two-view DBT, which included DM and tomosynthesis images, and three-view DM. Probability of malignancy and a BI-RADS score were assigned. Primary outcomes were area under the receiver operating characteristic curve (AUC) and benign and malignant recall rates. Results: The cohort included 121 cases: 37% were malignant and 63% were benign. Reader-averaged AUCs were 0.846 (95% confidence interval [CI] = 0.787–0.905) and 0.853 (95% CI = 0.802–0.904) for three-view DM and DBT, respectively. Benign and malignant recall rates were 53% and 74% for three-view DM and 52% and 75% for DBT, respectively. There was no difference in AUCs ( P = 0.692), and benign ( P = 1) and malignant ( P = 1) recall rates. Conclusion: In this retrospective initial study, the detection performance of two-view DBT and three-view DM were statistically equivalent. Future studies should determine whether three-view DM is a viable alternative to DBT for screening, given its cost and work-flow. … (more)
- Is Part Of:
- Acta radiologica. Volume 60:Number 9(2019)
- Journal:
- Acta radiologica
- Issue:
- Volume 60:Number 9(2019)
- Issue Display:
- Volume 60, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 9
- Issue Sort Value:
- 2019-0060-0009-0000
- Page Start:
- 1094
- Page End:
- 1101
- Publication Date:
- 2019-09
- Subjects:
- Breast -- screening -- digital breast tomosynthesis
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185118815315 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10900.xml