Investigation of quad-energy high-rate photon counting for X-ray computed tomography using a cadmium telluride detector. (December 2017)
- Record Type:
- Journal Article
- Title:
- Investigation of quad-energy high-rate photon counting for X-ray computed tomography using a cadmium telluride detector. (December 2017)
- Main Title:
- Investigation of quad-energy high-rate photon counting for X-ray computed tomography using a cadmium telluride detector
- Authors:
- Matsukiyo, Hiroshi
Sato, Eiichi
Oda, Yasuyuki
Yamaguchi, Satoshi
Sato, Yuichi
Hagiwara, Osahiko
Enomoto, Toshiyuki
Watanabe, Manabu
Kusachi, Shinya - Abstract:
- Abstract: To obtain four kinds of tomograms at four different X-ray energy ranges simultaneously, we have constructed a quad-energy (QE) X-ray photon counter with a cadmium telluride (CdTe) detector and four sets of comparators and microcomputers (MCs). X-ray photons are detected using the CdTe detector, and the event pulses produced using amplifiers are sent to four comparators simultaneously to regulate four threshold energies of 20, 33, 50 and 65 keV. Using this counter, the energy ranges are 20–33, 33–50, 50–65 and 65–100 keV; the maximum energy corresponds to the tube voltage. We performed QE computed tomography (QE-CT) at a tube voltage of 100 kV. Using a 0.5-mm-diam lead pinhole, four tomograms were obtained simultaneously at four energy ranges. K-edge CT using iodine and gadolinium media was carried out utilizing two energy ranges of 33–50 and 50–65 keV, respectively. At a tube voltage of 100 kV and a current of 60 μA, the count rate was 15.2 kilocounts per second (kcps), and the minimum count rates after penetrating objects in QE-CT were regulated to approximately 2 kcps by the tube current. Highlights: X-ray counter based on quad-energy-range selection has been constructed. Counter is realized by four-sets of comparators and microcomputers. Photon energy determination was carried out online using microcomputers. CT was performed for four X-ray energy ranges with high count rates. Iodine and gadolinium K-edge CT was accomplished simultaneously.
- Is Part Of:
- Applied radiation and isotopes. Volume 130(2017:Dec.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 130(2017:Dec.)
- Issue Display:
- Volume 130 (2017)
- Year:
- 2017
- Volume:
- 130
- Issue Sort Value:
- 2017-0130-0000-0000
- Page Start:
- 54
- Page End:
- 59
- Publication Date:
- 2017-12
- Subjects:
- X-ray photon counting -- CdTe detector -- Energy-selection electronics -- Quad-energy CT -- Penetrating-count regulation
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2017.09.011 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10874.xml