A comparison of methods to determine center of mass during pregnancy. (11th April 2018)
- Record Type:
- Journal Article
- Title:
- A comparison of methods to determine center of mass during pregnancy. (11th April 2018)
- Main Title:
- A comparison of methods to determine center of mass during pregnancy
- Authors:
- Catena, Robert D.
Connolly, Christopher P.
McGeorge, Kendra M.
Campbell, Nigel - Abstract:
- Abstract: Balance changes during pregnancy likely occur because of mass gains and mass distribution changes. However, to date there is no way of tracking balance through center of mass motion because no method is available to identify of the body center of mass throughout pregnancy. We compared methods for determining segment masses and torso center of mass location. The availability of a method for tracking these changes during pregnancy will make determining balance changes through center of mass motion an option for future pregnancy balance research. Thirty pregnant women from eight weeks gestation until birth were recruited for monthly anthropometric measurements, motion capture analysis of body segment locations, and force plate analysis of center of pressure during quiet standing and supine laying. From these measurements, we were able to compare regression, volume measurement, and weighted sum methods to calculate body center of mass throughout pregnancy. We found that mass changes around the trunk were most prevalent as expected, but mass changes throughout the body (especially the thighs) were also seen. Our findings also suggest that a series of anthropometric measurements first suggested by Pavol et al. (2002), in combination with quiet standing on a force plate, can be used to identify the needed components (segment masses and torso center of mass location in three dimensions) to calculate body center of mass changes during pregnancy. The results of this studyAbstract: Balance changes during pregnancy likely occur because of mass gains and mass distribution changes. However, to date there is no way of tracking balance through center of mass motion because no method is available to identify of the body center of mass throughout pregnancy. We compared methods for determining segment masses and torso center of mass location. The availability of a method for tracking these changes during pregnancy will make determining balance changes through center of mass motion an option for future pregnancy balance research. Thirty pregnant women from eight weeks gestation until birth were recruited for monthly anthropometric measurements, motion capture analysis of body segment locations, and force plate analysis of center of pressure during quiet standing and supine laying. From these measurements, we were able to compare regression, volume measurement, and weighted sum methods to calculate body center of mass throughout pregnancy. We found that mass changes around the trunk were most prevalent as expected, but mass changes throughout the body (especially the thighs) were also seen. Our findings also suggest that a series of anthropometric measurements first suggested by Pavol et al. (2002), in combination with quiet standing on a force plate, can be used to identify the needed components (segment masses and torso center of mass location in three dimensions) to calculate body center of mass changes during pregnancy. The results of this study will make tracking of center of mass motion a possibility for future pregnancy balance research. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 71(2018)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 71(2018)
- Issue Display:
- Volume 71, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 71
- Issue:
- 2018
- Issue Sort Value:
- 2018-0071-2018-0000
- Page Start:
- 217
- Page End:
- 224
- Publication Date:
- 2018-04-11
- Subjects:
- Pregnancy -- Anthropometry -- Center of mass -- Mass distribution -- Center of gravity
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2018.02.004 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10872.xml