Development and Validation of a Rapid Chemometrics Assisted RP-HPLC with PDA Detection Method for the Simultaneous Estimation of Pyridoxine HCl and Doxylamine Succinate in Bulk and Pharmaceutical Dosage Form. (23rd April 2014)
- Record Type:
- Journal Article
- Title:
- Development and Validation of a Rapid Chemometrics Assisted RP-HPLC with PDA Detection Method for the Simultaneous Estimation of Pyridoxine HCl and Doxylamine Succinate in Bulk and Pharmaceutical Dosage Form. (23rd April 2014)
- Main Title:
- Development and Validation of a Rapid Chemometrics Assisted RP-HPLC with PDA Detection Method for the Simultaneous Estimation of Pyridoxine HCl and Doxylamine Succinate in Bulk and Pharmaceutical Dosage Form
- Authors:
- Giriraj, P.
Sivakkumar, T. - Other Names:
- Takeuchi Toyohide Academic Editor.
- Abstract:
- Abstract : Simple, rapid, precise, and accurate RP-HPLC method was developed and optimized with the help of chemometric tool for the simultaneous estimation of pyridoxine HCl and doxylamine succinate in bulk and pharmaceutical dosage form. Optimization was done by central composite design in response surface methodology. Based on the trial and error, percentage of organic phase (methanol) in mobile phase, flow rate, and molarity of the buffer were selected as factors. Resolution and retention time were used for the estimation of system response during the optimization procedure. The optimized condition was used and the separation was carried out on phenomenex C18 column (150 × 4.6 mm; i.d, 5 μ particle size) using the mobile phase containing 49.37% of methanol and 50.63% of phosphate buffer (45.14 mM) at a flow rate of 1 mL/min. Retention time was found to be 1.884 minutes for pyridoxine HCl and 3.959 minutes for doxylamine succinate. The calibration curves were found to be linear from 10 to 70 μ g/mL and 10 to 90 μ g/mL for pyridoxine HCl and doxylamine succinate with their correlation coefficient values 0.9995 and 0.9997. LOD and LOQ were found to be 23.5 ng/mL and 71.1 ng/mL for pyridoxine HCl and 99.9 ng/mL and 302.6 ng/mL for doxylamine succinate.
- Is Part Of:
- Chromatography research international. Volume 2014(2014)
- Journal:
- Chromatography research international
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-04-23
- Subjects:
- Chromatographic analysis -- Periodicals
Chromatographic analysis -- Research -- Periodicals
Chromatographic analysis
Chromatographic analysis -- Research
Periodicals - Journal URLs:
- http://bibpurl.oclc.org/web/46175 ↗
https://www.hindawi.com/journals/cri/ ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%22B6CI%22&scope=site ↗ - DOI:
- 10.1155/2014/827895 ↗
- Languages:
- English
- ISSNs:
- 2090-3502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10879.xml