Development and Validation of Selective High Performance Liquid Chromatographic Method Using Photodiode Array Detection for Estimation of Aconitine in Polyherbal Ayurvedic Taila Preparations. (9th April 2012)
- Record Type:
- Journal Article
- Title:
- Development and Validation of Selective High Performance Liquid Chromatographic Method Using Photodiode Array Detection for Estimation of Aconitine in Polyherbal Ayurvedic Taila Preparations. (9th April 2012)
- Main Title:
- Development and Validation of Selective High Performance Liquid Chromatographic Method Using Photodiode Array Detection for Estimation of Aconitine in Polyherbal Ayurvedic Taila Preparations
- Authors:
- Dubey, Nitin
Dubey, Nidhi
Mehta, Rajendra - Other Names:
- Ozkan Sibel A. Academic Editor.
- Abstract:
- Abstract : A simple, sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed and validated for the analysis of aconitine in marketed Ayurvedic Taila (oil) formulations containing roots of Aconitum chasmanthum . Chromatography of methanolic extracts of these formulations was performed on C18 (5 μ m × 25 cm × 4.6 mm i.d) column using isocratic mobile phase consisting of (65 : 35% v/v) acetonitrile and buffer solution (aqueous 0.01 M ammonium bicarbonate buffer, adjusted to pH 9.6 using 30% ammonia solution) at a flow rate of 1 mL/min and SPD-10A V P photodiode array (PDA) UV-Visible detector. The analytical reference, aconitine, was quantified at 238 nm. The retention time of aconitine was about 42.54 min. The linear regression analysis data for the calibration plot showed a good linear relationship with correlation coefficient of 0.9989 in the concentration range of 15 to 90 μ g/mL for aconitine with respect to peak area. The limit of detection and limit of quantitation values were found to be 0.03 μ g/mL and 0.1 μ g/mL respectively. Repeatability of the method was found to be 0.551–1.689 RSD. Recovery values from 97.75–99.91% indicate excellent accuracy of the method. The developed HPLC method is accurate, precise and it can be successfully applied for the determination of aconitine in marketed ayurvedic oil formulations containing Aconitum chasmanthum .
- Is Part Of:
- Chromatography research international. Volume 2012(2012)
- Journal:
- Chromatography research international
- Issue:
- Volume 2012(2012)
- Issue Display:
- Volume 2012, Issue 2012 (2012)
- Year:
- 2012
- Volume:
- 2012
- Issue:
- 2012
- Issue Sort Value:
- 2012-2012-2012-0000
- Page Start:
- Page End:
- Publication Date:
- 2012-04-09
- Subjects:
- Chromatographic analysis -- Periodicals
Chromatographic analysis -- Research -- Periodicals
Chromatographic analysis
Chromatographic analysis -- Research
Periodicals - Journal URLs:
- http://bibpurl.oclc.org/web/46175 ↗
https://www.hindawi.com/journals/cri/ ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%22B6CI%22&scope=site ↗ - DOI:
- 10.1155/2012/157916 ↗
- Languages:
- English
- ISSNs:
- 2090-3502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10887.xml