Evaluation of bacterial presence on lead X-ray aprons utilised in the operating room via IBIS and standard culture methods. Issue 4 (July 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of bacterial presence on lead X-ray aprons utilised in the operating room via IBIS and standard culture methods. Issue 4 (July 2019)
- Main Title:
- Evaluation of bacterial presence on lead X-ray aprons utilised in the operating room via IBIS and standard culture methods
- Authors:
- Jain, Sameer
Rajfer, Rebecca A
Melton-Kreft, Rachel
Nistico, Laura
Miller, Mark C
Stoodley, Paul
Altman, Daniel T
Altman, Gregory T - Abstract:
- Background: Despite precautions, surgical procedures carry risk of infection. Radiation-protective lead aprons worn by operating personnel are a potential source of bacterial contamination and have not been fully evaluated. Aim/objective: To evaluate lead aprons as a source of bacterial contamination, identify organisms most commonly found on this source, and devise a method with which to lower the risk of contamination. Methods: In this basic science study, 20 randomly selected lead X-ray aprons were swabbed at three time points. The experimental treatment was with a hospital-grade disinfectant wipe. The samples were assessed for bacterial growth via traditional plating methods and mass spectrometry. Plates were graded on a scale of 0 to 4+ based on the number of quadrants with growth. Growth on one quadrant or more was considered contaminated. Findings/results: Bacteria were initially detected via IBIS on a majority of the aprons (32/40), most commonly Staphylococcus epidermidis and Propionibacterium acnes . Virulent organisms cultured were Methicillin-resistant Staphylococcus epidermidis (MRSE), Neisseria, Streptococcus viridans and pseudomonas. MRSE were detected on 5/20 of the samples. Immediately after treatment, the majority of aprons showed less bacterial contamination (0/20 standard culture positive; 13/20 IBIS positive) with some recurrence at the 6-h time point (2/20 standard culture positive, 16/20 IBIS positive). All MRSE detected initially was eradicated.Background: Despite precautions, surgical procedures carry risk of infection. Radiation-protective lead aprons worn by operating personnel are a potential source of bacterial contamination and have not been fully evaluated. Aim/objective: To evaluate lead aprons as a source of bacterial contamination, identify organisms most commonly found on this source, and devise a method with which to lower the risk of contamination. Methods: In this basic science study, 20 randomly selected lead X-ray aprons were swabbed at three time points. The experimental treatment was with a hospital-grade disinfectant wipe. The samples were assessed for bacterial growth via traditional plating methods and mass spectrometry. Plates were graded on a scale of 0 to 4+ based on the number of quadrants with growth. Growth on one quadrant or more was considered contaminated. Findings/results: Bacteria were initially detected via IBIS on a majority of the aprons (32/40), most commonly Staphylococcus epidermidis and Propionibacterium acnes . Virulent organisms cultured were Methicillin-resistant Staphylococcus epidermidis (MRSE), Neisseria, Streptococcus viridans and pseudomonas. MRSE were detected on 5/20 of the samples. Immediately after treatment, the majority of aprons showed less bacterial contamination (0/20 standard culture positive; 13/20 IBIS positive) with some recurrence at the 6-h time point (2/20 standard culture positive, 16/20 IBIS positive). All MRSE detected initially was eradicated. Discussion: Lead X-ray aprons worn in the operating room harbour bacteria. Disinfecting before use may prevent the introduction of virulent organisms to patients. Our proposed method of sanitising with a disinfectant wipe is quick and effective. … (more)
- Is Part Of:
- Journal of infection prevention. Volume 20:Issue 4(2019)
- Journal:
- Journal of infection prevention
- Issue:
- Volume 20:Issue 4(2019)
- Issue Display:
- Volume 20, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2019-0020-0004-0000
- Page Start:
- 191
- Page End:
- 196
- Publication Date:
- 2019-07
- Subjects:
- Lead apron -- X-ray -- IBIS -- FISH -- biofilm -- MRSE -- disinfectant -- wipe -- surgical site infection
Hospital buildings -- Sanitation -- Periodicals
Communicable diseases -- Prevention -- Periodicals
Nosocomial infections -- Prevention -- Periodicals
Cross infection -- Prevention -- Periodicals
616.9045 - Journal URLs:
- http://bji.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1757177419833163 ↗
- Languages:
- English
- ISSNs:
- 1757-1774
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10882.xml