A novel braided biodegradable stent for use in congenital heart disease: Short‐term results in porcine iliac artery. Issue 8 (12th April 2019)
- Record Type:
- Journal Article
- Title:
- A novel braided biodegradable stent for use in congenital heart disease: Short‐term results in porcine iliac artery. Issue 8 (12th April 2019)
- Main Title:
- A novel braided biodegradable stent for use in congenital heart disease: Short‐term results in porcine iliac artery
- Authors:
- Sun, Jing
Sun, Kun
Bai, Kai
Chen, Sun
Wang, Fujun
Zhao, Fan
Hong, Nanchao
Hu, Hanbo - Abstract:
- Abstract: To evaluate the properties and efficacy of a novel braided biodegradable stent (BBS) consisting of poly (p‐dioxanone) (PPDO) and polycaprolactone (PCL) for usage in children with congenital cardiovascular diseases. PCL/PPDO composite filaments were fabricated by coating PCL layers onto PPDO filaments, which were fused with PPDO monofilaments to form the BBS. Physical properties of BBSs including elastic recovery rate, deformation rate, and mechanical characteristics with adjunctive post‐dilation were evaluated by radial force‐tests. Ten BBS stents and 10 metallic wall stents (WS) as controls were implanted into the common carotid arteries of 10 pigs and angiography as well as histological examinations were performed 4 and 8 weeks after implantation. An 8 mm BBS with adjunctive post‐dilation had the best morphological retention and dimension stability being similar to an 8 mm WS. Luminal gain percentages of BBS and WS immediately, 4 weeks and 8 weeks after implantation were 20.44 ± 2.82% and 27.08 ± 0.88%, 12.34 ± 0.18% and 17.32 ± 8.24%, as well as −1.76 ± 2.45% and − 0.98 ± 3.23%. Luminal areas, internal elastic laminas, neointimal areas, neointimal thicknesses, and area stenosis were not significantly different at 4 weeks and 8 weeks after implantation. Injury and inflammation were similar in both groups and no malposition, thrombosis or dissection occurred. BBS with adjunctive post‐dilation showed good physical properties and mechanical stability noninferior toAbstract: To evaluate the properties and efficacy of a novel braided biodegradable stent (BBS) consisting of poly (p‐dioxanone) (PPDO) and polycaprolactone (PCL) for usage in children with congenital cardiovascular diseases. PCL/PPDO composite filaments were fabricated by coating PCL layers onto PPDO filaments, which were fused with PPDO monofilaments to form the BBS. Physical properties of BBSs including elastic recovery rate, deformation rate, and mechanical characteristics with adjunctive post‐dilation were evaluated by radial force‐tests. Ten BBS stents and 10 metallic wall stents (WS) as controls were implanted into the common carotid arteries of 10 pigs and angiography as well as histological examinations were performed 4 and 8 weeks after implantation. An 8 mm BBS with adjunctive post‐dilation had the best morphological retention and dimension stability being similar to an 8 mm WS. Luminal gain percentages of BBS and WS immediately, 4 weeks and 8 weeks after implantation were 20.44 ± 2.82% and 27.08 ± 0.88%, 12.34 ± 0.18% and 17.32 ± 8.24%, as well as −1.76 ± 2.45% and − 0.98 ± 3.23%. Luminal areas, internal elastic laminas, neointimal areas, neointimal thicknesses, and area stenosis were not significantly different at 4 weeks and 8 weeks after implantation. Injury and inflammation were similar in both groups and no malposition, thrombosis or dissection occurred. BBS with adjunctive post‐dilation showed good physical properties and mechanical stability noninferior to WS. In vivo evaluations showed that a BBS with post‐ballooning had similar short‐term outcomes as a WS. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 1667–1677, 2019. … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 107:Issue 8(2019)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 107:Issue 8(2019)
- Issue Display:
- Volume 107, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 107
- Issue:
- 8
- Issue Sort Value:
- 2019-0107-0008-0000
- Page Start:
- 1667
- Page End:
- 1677
- Publication Date:
- 2019-04-12
- Subjects:
- biodegradable stent -- poly (p‐dioxanone) -- congenital cardiovascular diseases -- endovascular intervention -- infants and young children
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4965 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbm.a.36682 ↗
- Languages:
- English
- ISSNs:
- 1549-3296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.720000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10884.xml