Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning. Issue 6 (23rd May 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning. Issue 6 (23rd May 2019)
- Main Title:
- Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
- Authors:
- Huang, Jessie Y.
Dunkerley, David
Smilowitz, Jennifer B. - Abstract:
- Abstract: The RayStation treatment planning system implements a Monte Carlo (MC) algorithm for electron dose calculations. For a TrueBeam accelerator, beam modeling was performed for four electron energies (6, 9, 12, and 15 MeV), and the dose calculation accuracy was tested for a range of geometries. The suite of validation tests included those tests recommended by AAPM's Medical Physics Practice Guideline 5.a, but extended beyond these tests in order to validate the MC algorithm in more challenging geometries. For MPPG 5.a testing, calculation accuracy was evaluated for square cutouts of various sizes, two custom cutout shapes, oblique incidence, and heterogenous media (cork). In general, agreement between ion chamber measurements and RayStation dose calculations was excellent and well within suggested tolerance limits. However, this testing did reveal calculation errors for the output of small cutouts. Of the 312 output factors evaluated for square cutouts, 20 (6.4%) were outside of 3% and 5 (1.6%) were outside of 5%, with these larger errors generally being for the smallest cutout sizes within a given applicator. Adjustment of beam modeling parameters did not fix these calculation errors, nor does the planning software allow the user to input correction factors as a function of field size. Additional validation tests included several complex phantom geometries (triangular nose phantom, lung phantom, curved breast phantom, and cortical bone phantom), designed to test theAbstract: The RayStation treatment planning system implements a Monte Carlo (MC) algorithm for electron dose calculations. For a TrueBeam accelerator, beam modeling was performed for four electron energies (6, 9, 12, and 15 MeV), and the dose calculation accuracy was tested for a range of geometries. The suite of validation tests included those tests recommended by AAPM's Medical Physics Practice Guideline 5.a, but extended beyond these tests in order to validate the MC algorithm in more challenging geometries. For MPPG 5.a testing, calculation accuracy was evaluated for square cutouts of various sizes, two custom cutout shapes, oblique incidence, and heterogenous media (cork). In general, agreement between ion chamber measurements and RayStation dose calculations was excellent and well within suggested tolerance limits. However, this testing did reveal calculation errors for the output of small cutouts. Of the 312 output factors evaluated for square cutouts, 20 (6.4%) were outside of 3% and 5 (1.6%) were outside of 5%, with these larger errors generally being for the smallest cutout sizes within a given applicator. Adjustment of beam modeling parameters did not fix these calculation errors, nor does the planning software allow the user to input correction factors as a function of field size. Additional validation tests included several complex phantom geometries (triangular nose phantom, lung phantom, curved breast phantom, and cortical bone phantom), designed to test the ability of the algorithm to handle high density heterogeneities and irregular surface contours. In comparison to measurements with radiochromic film, RayStation showed good agreement, with an average of 89.3% pixels passing for gamma analysis (3%/3mm) across four phantom geometries. The MC algorithm was able to accurately handle the presence of irregular surface contours (curved cylindrical phantom and a triangular nose phantom), as well as heterogeneities (cork and cortical bone). … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 6(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 6(2019)
- Issue Display:
- Volume 20, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2019-0020-0006-0000
- Page Start:
- 184
- Page End:
- 193
- Publication Date:
- 2019-05-23
- Subjects:
- electron treatment planning -- heterogeneous dose calculation -- Monte Carlo -- MPPG 5.a validation
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12622 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10861.xml