Evaluation of Healing Rates and Safety With a Bioinductive Collagen Patch for Large and Massive Rotator Cuff Tears: 2-Year Safety and Clinical Outcomes. Issue 8 (July 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of Healing Rates and Safety With a Bioinductive Collagen Patch for Large and Massive Rotator Cuff Tears: 2-Year Safety and Clinical Outcomes. Issue 8 (July 2019)
- Main Title:
- Evaluation of Healing Rates and Safety With a Bioinductive Collagen Patch for Large and Massive Rotator Cuff Tears: 2-Year Safety and Clinical Outcomes
- Authors:
- Thon, Stephen G.
O'Malley, Larry
O'Brien, Michael J.
Savoie, Felix H. - Abstract:
- Background: Failure of repair of large and massive rotator cuff tears is a challenging problem within orthopaedics. Poor tendon tissue and vascularity are known causes for failure of rotator cuff repairs. Purpose: To assess the safety, outcomes, and healing rates when large and massive rotator cuff repairs are augmented with a bioinductive collagen scaffold patch in a proof-of-principle design. Study Design: Case series; Level of evidence, 4. Methods: Twenty-three patients undergoing repair of full-thickness large (2-tendon) or massive (3-tendon) rotator cuff tears augmented with a bioinductive collagen patch were enrolled in a prospective single-arm proof-of-principle study. No partial repairs were performed, and a complete rotator cuff repair was successfully achieved in each case. Sixteen patients underwent revision rotator cuff repairs versus 7 primary repairs. Safety was determined by any implant-related adverse event. A single magnetic resonance imaging (MRI) scan was utilized to confirm tendon healing and thickness at a minimum of 6 months postoperatively. Postoperative ultrasound (US) was used in office by the treating surgeon to assess tendon thickness at 3-, 6-, 12-, and 24-month intervals. American Shoulder and Elbow Surgeons (ASES) scores were collected at final follow-up. Results: Overall, a 96% (22 of 23) healing rate was confirmed on US and MRI. However, incidence of treatment clinical failure was 9% (2 of 23), as 1 patient's tendon healed but eventuallyBackground: Failure of repair of large and massive rotator cuff tears is a challenging problem within orthopaedics. Poor tendon tissue and vascularity are known causes for failure of rotator cuff repairs. Purpose: To assess the safety, outcomes, and healing rates when large and massive rotator cuff repairs are augmented with a bioinductive collagen scaffold patch in a proof-of-principle design. Study Design: Case series; Level of evidence, 4. Methods: Twenty-three patients undergoing repair of full-thickness large (2-tendon) or massive (3-tendon) rotator cuff tears augmented with a bioinductive collagen patch were enrolled in a prospective single-arm proof-of-principle study. No partial repairs were performed, and a complete rotator cuff repair was successfully achieved in each case. Sixteen patients underwent revision rotator cuff repairs versus 7 primary repairs. Safety was determined by any implant-related adverse event. A single magnetic resonance imaging (MRI) scan was utilized to confirm tendon healing and thickness at a minimum of 6 months postoperatively. Postoperative ultrasound (US) was used in office by the treating surgeon to assess tendon thickness at 3-, 6-, 12-, and 24-month intervals. American Shoulder and Elbow Surgeons (ASES) scores were collected at final follow-up. Results: Overall, a 96% (22 of 23) healing rate was confirmed on US and MRI. However, incidence of treatment clinical failure was 9% (2 of 23), as 1 patient's tendon healed but eventually underwent additional surgery. There were no adverse events attributed to the implant reported. Final US rotator cuff thickness was 7.28 ± 0.85 mm (mean ± SD), and final MRI rotator cuff thickness was 5.13 ± 1.06 mm. The mean ASES score at final follow-up was 82.87 ± 16.68 (range, 53.33-100). Conclusion: No complications attributed to the implant were reported, and new tendon formation was apparent on US and MRI, with relatively high healing rates at 2-year follow-up. Arthroscopic application of this bioinductive collagen scaffold when combined with rotator cuff repair is a safe and effective treatment for healing of large and massive rotator cuff repairs. … (more)
- Is Part Of:
- American journal of sports medicine. Volume 47:Issue 8(2019)
- Journal:
- American journal of sports medicine
- Issue:
- Volume 47:Issue 8(2019)
- Issue Display:
- Volume 47, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 8
- Issue Sort Value:
- 2019-0047-0008-0000
- Page Start:
- 1901
- Page End:
- 1908
- Publication Date:
- 2019-07
- Subjects:
- shoulder -- rotator cuff -- collagen scaffold -- bioinductive implant
Sports medicine -- Periodicals
Sports injuries -- Periodicals
Orthopedic surgery -- Periodicals
617.102705 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0363-5465 ↗
http://ajs.sagepub.com ↗
http://www.ajsm.org ↗
http://www.sagepub.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1177/0363546519850795 ↗
- Languages:
- English
- ISSNs:
- 0363-5465
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10851.xml