Successful defibrillation verification in subcutaneous implantable cardioverter‐defibrillator recipients by low‐energy shocks. Issue 6 (25th April 2019)
- Record Type:
- Journal Article
- Title:
- Successful defibrillation verification in subcutaneous implantable cardioverter‐defibrillator recipients by low‐energy shocks. Issue 6 (25th April 2019)
- Main Title:
- Successful defibrillation verification in subcutaneous implantable cardioverter‐defibrillator recipients by low‐energy shocks
- Authors:
- Biffi, Mauro
Ziacchi, Matteo
Angeletti, Andrea
Castelli, Andrea
Massaro, Giulia
Martignani, Cristian
Lovecchio, Mariolina
Valsecchi, Sergio
Diemberger, Igor - Abstract:
- Abstract: Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) is an effective alternative to the transvenous one. Defibrillation efficacy depends on maximum device output and on the optimal device location at device implantation. Hypothesis: We sought to investigate the defibrillation safety margin in real life clinical practice. Methods: We sought to understand what is the efficacy of induced ventricular fibrillation (VF) termination at S‐ICD implantation using lower energies than the recommended 65 J. Results: Sixty‐four consecutive S‐ICD recipients underwent VF termination attempts at implantation with energies ranging from 20 to 50 J. Overall, VF termination occurred in 84% of patients with ≤40 J, in 88% with 45 J, and in 100% with 60 J. Intermuscular S‐ICD placement was associated with 94% VF termination at ≤40 J. An ejection fraction <35% was associated to higher energy requirement for defibrillation; however, an intermuscular S‐ICD placement conferred 90% defibrillation efficacy at 31 ± 5 J in this patients subset. Conclusions: This is a hypothesis‐generating observation that prompts a methodologically correct investigation to prove that a 60 J output S‐ICD can provide an adequate safety margin to terminate VF in clinical practice. This would enable superior device longevity and/or device downsizing for pediatric/small size patients.
- Is Part Of:
- Clinical cardiology. Volume 42:Issue 6(2019)
- Journal:
- Clinical cardiology
- Issue:
- Volume 42:Issue 6(2019)
- Issue Display:
- Volume 42, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2019-0042-0006-0000
- Page Start:
- 612
- Page End:
- 617
- Publication Date:
- 2019-04-25
- Subjects:
- defibrillation test -- energy -- implantable defibrillator -- subcutaneous -- ventricular fibrillation
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.23184 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10864.xml