ICONE‐SRS: Development of inverse treatment planning for cone‐based stereotactic radiosurgery. Issue 6 (16th May 2019)
- Record Type:
- Journal Article
- Title:
- ICONE‐SRS: Development of inverse treatment planning for cone‐based stereotactic radiosurgery. Issue 6 (16th May 2019)
- Main Title:
- ICONE‐SRS: Development of inverse treatment planning for cone‐based stereotactic radiosurgery
- Authors:
- Lausch, Anthony
Nghiem, Brian
Nielsen, Michelle - Abstract:
- Abstract: Purpose: At present, commercially available treatment planning systems (TPS) only offer manual planning functionality for cone‐based stereotactic radiosurgery (SRS) leading to labor intensive treatment planning. Our objective was to reduce treatment planning time through development of a simple inverse TPS for cone‐based SRS. Methods: The iCONE TPS was developed using MATLAB (R2015a, The MathWorks Inc.) and serves as an inverse planning adjunct to a commercially available TPS. Simulated annealing is used to determine optimal table angle, gantry start and stop angles, and cone sizes for a user‐defined number of non‐coplanar arcs relative to user‐defined dose objectives. iCONE and clinically generated plans were compared through a retrospective planning study of 60 patients treated for 1–3 brain metastases (total of 100 lesions). Results: Planning target volume (PTV) coverage was enforced for all plans through normalization. PTV maximum dose was constrained to be within 120%–135% of the prescription dose. The median conformity index for iCONE plans was 1.35, 1.33, and 1.32 for 1, 2, and 3‐target cases respectively corresponding to a median increase of 0.05 (range = −0.1 to 0.5, P < 0.05), 0.06 (range = −0.83 to 0.53, P < 0.05), and 0.03 (range = −1.21 to 0.74, P > 0.05) relative to the clinical plans. No clinically significant differences were found with respect to the dose to organs‐at‐risk. Median iCONE planning times were approximately a factor of five lowerAbstract: Purpose: At present, commercially available treatment planning systems (TPS) only offer manual planning functionality for cone‐based stereotactic radiosurgery (SRS) leading to labor intensive treatment planning. Our objective was to reduce treatment planning time through development of a simple inverse TPS for cone‐based SRS. Methods: The iCONE TPS was developed using MATLAB (R2015a, The MathWorks Inc.) and serves as an inverse planning adjunct to a commercially available TPS. Simulated annealing is used to determine optimal table angle, gantry start and stop angles, and cone sizes for a user‐defined number of non‐coplanar arcs relative to user‐defined dose objectives. iCONE and clinically generated plans were compared through a retrospective planning study of 60 patients treated for 1–3 brain metastases (total of 100 lesions). Results: Planning target volume (PTV) coverage was enforced for all plans through normalization. PTV maximum dose was constrained to be within 120%–135% of the prescription dose. The median conformity index for iCONE plans was 1.35, 1.33, and 1.32 for 1, 2, and 3‐target cases respectively corresponding to a median increase of 0.05 (range = −0.1 to 0.5, P < 0.05), 0.06 (range = −0.83 to 0.53, P < 0.05), and 0.03 (range = −1.21 to 0.74, P > 0.05) relative to the clinical plans. No clinically significant differences were found with respect to the dose to organs‐at‐risk. Median iCONE planning times were approximately a factor of five lower than consensus estimates for manual planning provided by local experienced SRS planners. Conclusions: A simple inverse TPS for cone‐based SRS was developed. Plan quality was found to be similar to manually generated plans; however, degradation was observed in some cases highlighting the need for continued oversight and manual adjustment by experienced planners if implemented in the clinic. A factor of five reduction in treatment planning time was estimated. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 6(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 6(2019)
- Issue Display:
- Volume 20, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2019-0020-0006-0000
- Page Start:
- 70
- Page End:
- 78
- Publication Date:
- 2019-05-16
- Subjects:
- cones -- inverse planning -- simulated annealing -- stereotactic radiosurgery
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12609 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10861.xml