Phase transformation and fracture load of stock and CAD/CAM‐customized zirconia abutments after 1 year of clinical function. Issue 6 (3rd May 2019)
- Record Type:
- Journal Article
- Title:
- Phase transformation and fracture load of stock and CAD/CAM‐customized zirconia abutments after 1 year of clinical function. Issue 6 (3rd May 2019)
- Main Title:
- Phase transformation and fracture load of stock and CAD/CAM‐customized zirconia abutments after 1 year of clinical function
- Authors:
- Schepke, Ulf
Gresnigt, Marco M. M.
Browne, Wesley R.
Abdolahzadeh, Shaghayegh
Nijkamp, Joey
Cune, Marco S. - Abstract:
- Abstract: Objectives: Functional loading and low‐temperature degradation may give rise to impaired clinical long‐term service of zirconia implant abutments. The aim of this study was to compare the fracture strength (primary outcome measure) and the volume percentage of monoclinic surface zirconia (m‐ZrO2 ) of stock and CAD/CAM‐customized zirconia implant abutments that functioned clinically for 1 year with geometrically identical pristine controls in an ex vivo experiment. Material and methods: Twenty‐three stock (ZirDesign™) and 23 CAD/CAM‐customized (Atlantis™) zirconia implant abutments were retrieved after 1 year of clinical service. They were compared with pristine copies with respect to the volume fraction of the monoclinic phase using Raman spectroscopy and their fracture load by means of a single load‐to‐fracture test. Failure analysis was performed using optical and SEM microscopy. After verification of normal distribution, paired t tests were used for comparison of fracture loads between pristine and clinically aged specimen. All statistical tests employed a level of significance of α = 0.05. Results: The fracture loads of the stock zirconia abutments were significantly ( p < 0.05) reduced to 78.8% ( SD 29.5%) after one year of clinical function. For the CAD/CAM abutments, no reduction in fracture load was found. No m‐ZrO2 volume percentages beyond the detection threshold of 5% were observed in any of the samples. Conclusions: After 1 year of clinical service,Abstract: Objectives: Functional loading and low‐temperature degradation may give rise to impaired clinical long‐term service of zirconia implant abutments. The aim of this study was to compare the fracture strength (primary outcome measure) and the volume percentage of monoclinic surface zirconia (m‐ZrO2 ) of stock and CAD/CAM‐customized zirconia implant abutments that functioned clinically for 1 year with geometrically identical pristine controls in an ex vivo experiment. Material and methods: Twenty‐three stock (ZirDesign™) and 23 CAD/CAM‐customized (Atlantis™) zirconia implant abutments were retrieved after 1 year of clinical service. They were compared with pristine copies with respect to the volume fraction of the monoclinic phase using Raman spectroscopy and their fracture load by means of a single load‐to‐fracture test. Failure analysis was performed using optical and SEM microscopy. After verification of normal distribution, paired t tests were used for comparison of fracture loads between pristine and clinically aged specimen. All statistical tests employed a level of significance of α = 0.05. Results: The fracture loads of the stock zirconia abutments were significantly ( p < 0.05) reduced to 78.8% ( SD 29.5%) after one year of clinical function. For the CAD/CAM abutments, no reduction in fracture load was found. No m‐ZrO2 volume percentages beyond the detection threshold of 5% were observed in any of the samples. Conclusions: After 1 year of clinical service, no difference in fracture strength of the CAD/CAM‐customized zirconia implant abutments could be demonstrated, whereas the stock zirconia abutments decreased considerably in fracture strength. No substantial tetragonal‐to‐monoclinic transformation was observed. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 30:Issue 6(2019)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 30:Issue 6(2019)
- Issue Display:
- Volume 30, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2019-0030-0006-0000
- Page Start:
- 559
- Page End:
- 569
- Publication Date:
- 2019-05-03
- Subjects:
- biomaterials -- clinical research -- clinical trials -- material sciences -- prosthodontics -- surface chemistry
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.13442 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10846.xml