Investigating the detection limit of subsurface holes under graphite with atomic force acoustic microscopy. Issue 22 (29th May 2019)
- Record Type:
- Journal Article
- Title:
- Investigating the detection limit of subsurface holes under graphite with atomic force acoustic microscopy. Issue 22 (29th May 2019)
- Main Title:
- Investigating the detection limit of subsurface holes under graphite with atomic force acoustic microscopy
- Authors:
- Yip, Kevin
Cui, Teng
Sun, Yu
Filleter, Tobin - Abstract:
- Abstract : The subsurface imaging capabilities of atomic force acoustic microscopy (AFAM) was investigated by imaging graphite flakes suspended over holes in a silicon dioxide substrate. Abstract : The subsurface imaging capabilities of atomic force acoustic microscopy (AFAM) was investigated by imaging graphite flakes suspended over holes in a silicon dioxide substrate. The graphite thickness and the hole size were varied to determine the detection limit on the maximum graphite thickness and the smallest detectable hole size. Parameters including operating frequency, eigenmode, contact force, and cantilever stiffness were investigated for their influence of defect detection. AFAM was reliably able to detect 2.5 μm diameter holes through a maximum graphite thickness of 570 nm and sub 100 nm holes through 140 nm of graphite. The smallest detectable defect size was a 50 nm hole covered by an 80 nm thick graphite flake. Increasing the graphite thickness and decreasing the hole size both resulted in a decrease in subsurface contrast. However, the non-linear trend observed from increasing the graphite thickness indicates thickness has a greater effect on subsurface defect detection than variations in defect size. Through investigating various parameters, we have found certain cases to increase the observed contrast of the embedded subsurface holes, however the smallest detectable defect size remained the same. This technique's ability to reveal sub 100 nm defects buried underAbstract : The subsurface imaging capabilities of atomic force acoustic microscopy (AFAM) was investigated by imaging graphite flakes suspended over holes in a silicon dioxide substrate. Abstract : The subsurface imaging capabilities of atomic force acoustic microscopy (AFAM) was investigated by imaging graphite flakes suspended over holes in a silicon dioxide substrate. The graphite thickness and the hole size were varied to determine the detection limit on the maximum graphite thickness and the smallest detectable hole size. Parameters including operating frequency, eigenmode, contact force, and cantilever stiffness were investigated for their influence of defect detection. AFAM was reliably able to detect 2.5 μm diameter holes through a maximum graphite thickness of 570 nm and sub 100 nm holes through 140 nm of graphite. The smallest detectable defect size was a 50 nm hole covered by an 80 nm thick graphite flake. Increasing the graphite thickness and decreasing the hole size both resulted in a decrease in subsurface contrast. However, the non-linear trend observed from increasing the graphite thickness indicates thickness has a greater effect on subsurface defect detection than variations in defect size. Through investigating various parameters, we have found certain cases to increase the observed contrast of the embedded subsurface holes, however the smallest detectable defect size remained the same. This technique's ability to reveal sub 100 nm defects buried under graphite has previously only been demonstrated in much softer polymer systems. … (more)
- Is Part Of:
- Nanoscale. Volume 11:Issue 22(2019)
- Journal:
- Nanoscale
- Issue:
- Volume 11:Issue 22(2019)
- Issue Display:
- Volume 11, Issue 22 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 22
- Issue Sort Value:
- 2019-0011-0022-0000
- Page Start:
- 10961
- Page End:
- 10967
- Publication Date:
- 2019-05-29
- Subjects:
- Nanoscience -- Periodicals
Nanotechnology -- Periodicals
620.505 - Journal URLs:
- http://www.rsc.org/Publishing/Journals/NR/Index.asp ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9nr03730f ↗
- Languages:
- English
- ISSNs:
- 2040-3364
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9830.266000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10835.xml