Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors. (June 2019)
- Record Type:
- Journal Article
- Title:
- Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors. (June 2019)
- Main Title:
- Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors
- Authors:
- Lisson, Christoph G
Lisson, Catharina S
Kleiner, Sebastian
Regier, Marc
Beer, Meinrad
Schmidt, Stefan A - Abstract:
- Background: Iterative scatter correction (ISC) is a new technique applicable to plain radiography; comparable to iterative reconstruction for computed tomography, it promises dose reduction and image quality improvement. ISC for bedside chest X-rays has been applied and evaluated for some time and has recently been commercially offered for plain skeletal radiography. Purpose: To analyze the potential of ISC for plain skeletal radiography with regard to image quality improvement, dose reduction, and replacement for an antiscatter grid. Material and Methods: A total of 385 radiographs with different imaging protocols of the pelvis and cervical spine were acquired from 20 body donors. Radiographs were rated by four radiologists. Ratings were analyzed with visual grading characteristics (VGC) analysis. The area under the VGC curve was used as a measure of difference in image quality. Results: Without ISC, the grid-less images were rated significantly worse than their grid-based counterparts (0.389, P = 0.005); adding ISC made image quality equal (0.498; P = 0.963). In grid-less imaging, reduction of dose by 50% led to significant image quality impairment (0.415, P = 0.001); this was fully counterbalanced when ISC was added (0.512; P = 0.588). Conclusion: ISC for plain skeletal radiography has the ability to replace the antiscatter grid without image quality impairment, to improve image quality in grid-less imaging, and to reduce patient radiation dose by 50% withoutBackground: Iterative scatter correction (ISC) is a new technique applicable to plain radiography; comparable to iterative reconstruction for computed tomography, it promises dose reduction and image quality improvement. ISC for bedside chest X-rays has been applied and evaluated for some time and has recently been commercially offered for plain skeletal radiography. Purpose: To analyze the potential of ISC for plain skeletal radiography with regard to image quality improvement, dose reduction, and replacement for an antiscatter grid. Material and Methods: A total of 385 radiographs with different imaging protocols of the pelvis and cervical spine were acquired from 20 body donors. Radiographs were rated by four radiologists. Ratings were analyzed with visual grading characteristics (VGC) analysis. The area under the VGC curve was used as a measure of difference in image quality. Results: Without ISC, the grid-less images were rated significantly worse than their grid-based counterparts (0.389, P = 0.005); adding ISC made image quality equal (0.498; P = 0.963). In grid-less imaging, reduction of dose by 50% led to significant image quality impairment (0.415, P = 0.001); this was fully counterbalanced when ISC was added (0.512; P = 0.588). Conclusion: ISC for plain skeletal radiography has the ability to replace the antiscatter grid without image quality impairment, to improve image quality in grid-less imaging, and to reduce patient radiation dose by 50% without substantial loss in image quality. … (more)
- Is Part Of:
- Acta radiologica. Volume 60:Number 6(2019)
- Journal:
- Acta radiologica
- Issue:
- Volume 60:Number 6(2019)
- Issue Display:
- Volume 60, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 6
- Issue Sort Value:
- 2019-0060-0006-0000
- Page Start:
- 735
- Page End:
- 741
- Publication Date:
- 2019-06
- Subjects:
- Skeletal – appendicular -- skeletal – axial -- radiation safety -- digital radiography -- computer-assisted image processing -- technology assessments
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185118796668 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10829.xml