Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning. Issue 10 (October 2016)
- Main Title:
- Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning
- Authors:
- Modabber, Ali
Peters, Florian
Kniha, Kristian
Goloborodko, Evgeny
Ghassemi, Alireza
Lethaus, Bernd
Hölzle, Frank
Möhlhenrich, Stephan Christian - Abstract:
- Abstract: Purpose: Numerous three-dimensional (3D) facial scanners have emerged on the market; however, publications evaluating their accuracies are sparse. In this study, the accuracy of two 3D scanners used in facial scanning was evaluated. Materials and methods: A test specimen was attached at the right cheek and the forehead of 41 volunteers. These volunteers were scanned with Artec EVA ® and FaceScan3D ® . The acquired data were aligned to a 3D model of the test specimen for comparing the mean error, original length and width and angles to the measured values. Results: The mean error in Best Fit alignment is significantly lower using Artec EVA ( p < 0.001) for both test specimens. The deviation from the original length and width is significantly lower for the test specimens ( p < 0.01) when measured with Artec EVA. The aberration of the angles measured between the front plane and the side plane is significantly lower when measured with Artec EVA ( p < 0.001). Captured with Artec EVA the discrepancy between the original angle and the angle measured between the side planes to each other is significantly lower ( p < 0.01). Conclusions: Scanning with Artec EVA leads to more accurate 3D models as compared to scanning with FaceScan3D. The exactness achieved by both scanners is comparable to other scanners mentioned in literature.
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 44:Issue 10(2016)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 44:Issue 10(2016)
- Issue Display:
- Volume 44, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 10
- Issue Sort Value:
- 2016-0044-0010-0000
- Page Start:
- 1719
- Page End:
- 1724
- Publication Date:
- 2016-10
- Subjects:
- 3D-scanner -- Accuracy -- Artec EVA -- FaceScan3D
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2016.08.008 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10799.xml