Measuring zygomaticomaxillary complex symmetry three-dimensionally with the use of mirroring and surface based matching techniques. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- Measuring zygomaticomaxillary complex symmetry three-dimensionally with the use of mirroring and surface based matching techniques. Issue 10 (October 2016)
- Main Title:
- Measuring zygomaticomaxillary complex symmetry three-dimensionally with the use of mirroring and surface based matching techniques
- Authors:
- Ho, Jean Pierre T.F.
Schreurs, Ruud
Milstein, Dan M.J.
Dubois, Leander
Maal, Thomas J.J.
de Lange, Jan
Becking, Alfred G. - Abstract:
- Abstract: Objective: The study aim was to validate a new method for measuring zygomaticomaxillary complex (ZMC) symmetry, which can be helpful in analyzing ZMC fractures. Methods: Three-dimensional virtual hard-tissue models were reconstructed from computed tomography (CT) datasets of 26 healthy individuals. Models were mirrored and superimposed. Absolute average distance (AD) and 90th percentile distance (NPD) were used to measure overall and maximal symmetry. The Intraclass Correlation Coefficient (ICC) was calculated to measure interobserver consistency. In order to determine whether this technique is applicable in ZMC fracture cases, 10 CT datasets of individuals with a unilateral ZMC fracture were analyzed. Results: For the unaffected group the mean AD was 0.84 ± 0.29 mm (95% CI 0.72–0.96) and the mean NPD was 1.58 ± 0.43 mm (95% CI 1.41–1.76). The ICC was 0.97 (0.94–0.98 as 95% CI), indicating almost perfect interobserver agreement. In the affected group the mean AD was 2.97 ± 1.76 mm (95% CI 1.71–4.23) and the mean NPD was 6.12 ± 3.42 mm (95% CI 3.67–8.57). The affected group showed near-perfect interobserver agreement with an ICC of 0.996 (0.983–0.999 as 95% CI). Conclusions: The method presented is an accurate instrument for evaluation of ZMC symmetry, which can be helpful for advanced diagnostics and treatment evaluation.
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 44:Issue 10(2016)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 44:Issue 10(2016)
- Issue Display:
- Volume 44, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 10
- Issue Sort Value:
- 2016-0044-0010-0000
- Page Start:
- 1706
- Page End:
- 1712
- Publication Date:
- 2016-10
- Subjects:
- Symmetry -- Zygomaticomaxillary complex -- Computer-assisted surgery -- Surface-based matching -- Iterative closest point
AD average distance -- AMC Academic Medical Center, University of Amsterdam -- CAS computer-assisted surgery -- CI confidence interval -- CT computed tomography -- DICOM digital imaging and communications in medicine -- FOV field of view -- ICC interclass correlation coefficients -- ICP iterative closest point -- kV kilovolt -- mA milliampere -- mm millimeter -- NPD 90th percentile distance -- SBM surface-based matching -- ZMC zygomatic complex -- 2D 2-dimensional -- 3D 3-dimensional
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2016.07.034 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10798.xml