Vaginal cervico-isthmic cerclage versus McDonald cerclage in women with a previous failure of prophylactic cerclage: A retrospective study. (September 2017)
- Record Type:
- Journal Article
- Title:
- Vaginal cervico-isthmic cerclage versus McDonald cerclage in women with a previous failure of prophylactic cerclage: A retrospective study. (September 2017)
- Main Title:
- Vaginal cervico-isthmic cerclage versus McDonald cerclage in women with a previous failure of prophylactic cerclage: A retrospective study
- Authors:
- Capmas, Perrine
Letendre, Irène
Leray, Camille
Deffieux, Xavier
Duminil, Laura
Subtil, Damien
Fernandez, Hervé - Abstract:
- Abstract: Aim: Compare preterm births before 30 weeks of gestation in women with a previous failed McDonald cerclage that benefit from another McDonald cerclage (or simplified Shirodkar cerclage) or a vaginal cervico-isthmic cerclage. Methods: Women with a cerclage performed at the end of the first trimester of a singleton pregnancy with a previous failed prophylactic McDonald cerclage were included in this mutlicenric study involving four teaching hospitals. Comparisons between groups were done using a chi square test and a student t -test. Results: We enrolled130 women, 85 in the vaginal cervico-isthmic cerclage group and 45 in the classic cerclage group. There was no significant difference in the rate of delivery after 30 weeks of gestation (92 versus 93% p = 0.75). However in the cervico isthmic cerclage, women were significantly older, presented more late foetal loss and fewer live children in the cervico-isthmic cerclage group. Rate of antenatal hospitalization andantenatal corticotherapy were significantly higher in the classic cerclage group (69% versus 46%, p < 0.05 and 56% versus 29%, p < 0.05). Conclusions: Rate of delivery before 30 weeks of gestation was not significantly different between the two groups, but women in the vaginal cervico-isthmic cerclage group seem to be at higher risk for late foetal loss or premature delivery. This procedure generates less threatened premature delivery, thus, less hospitalization and antenatal corticotherapy. These argumentsAbstract: Aim: Compare preterm births before 30 weeks of gestation in women with a previous failed McDonald cerclage that benefit from another McDonald cerclage (or simplified Shirodkar cerclage) or a vaginal cervico-isthmic cerclage. Methods: Women with a cerclage performed at the end of the first trimester of a singleton pregnancy with a previous failed prophylactic McDonald cerclage were included in this mutlicenric study involving four teaching hospitals. Comparisons between groups were done using a chi square test and a student t -test. Results: We enrolled130 women, 85 in the vaginal cervico-isthmic cerclage group and 45 in the classic cerclage group. There was no significant difference in the rate of delivery after 30 weeks of gestation (92 versus 93% p = 0.75). However in the cervico isthmic cerclage, women were significantly older, presented more late foetal loss and fewer live children in the cervico-isthmic cerclage group. Rate of antenatal hospitalization andantenatal corticotherapy were significantly higher in the classic cerclage group (69% versus 46%, p < 0.05 and 56% versus 29%, p < 0.05). Conclusions: Rate of delivery before 30 weeks of gestation was not significantly different between the two groups, but women in the vaginal cervico-isthmic cerclage group seem to be at higher risk for late foetal loss or premature delivery. This procedure generates less threatened premature delivery, thus, less hospitalization and antenatal corticotherapy. These arguments are important for women with previous pregnancy loss. … (more)
- Is Part Of:
- European journal of obstetrics, gynecology, and reproductive biology. Volume 216(2017)
- Journal:
- European journal of obstetrics, gynecology, and reproductive biology
- Issue:
- Volume 216(2017)
- Issue Display:
- Volume 216, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 216
- Issue:
- 2017
- Issue Sort Value:
- 2017-0216-2017-0000
- Page Start:
- 27
- Page End:
- 32
- Publication Date:
- 2017-09
- Subjects:
- Cerclage -- Cervico-isthmic cerclage -- Late foetal loss -- Premature delivery
Obstetrics -- Periodicals
Gynecology -- Periodicals
Reproductive health -- Periodicals
Gynecology -- Periodicals
Obstetrics -- Periodicals
Reproduction -- Periodicals
Obstétrique -- Périodiques
Gynécologie -- Périodiques
Reproduction -- Périodiques
Verloskunde
Gynaecologie
Voortplanting (biologie)
Gynecology
Obstetrics
Reproduction
Electronic journals
Periodicals
Electronic journals
618.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03012115 ↗
http://www.ingentaconnect.com/content/els/00282243 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03012115 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03012115 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejogrb.2017.06.037 ↗
- Languages:
- English
- ISSNs:
- 0301-2115
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.733000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10772.xml