In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application. (January 2018)
- Record Type:
- Journal Article
- Title:
- In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application. (January 2018)
- Main Title:
- In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application
- Authors:
- Liebsch, Christian
Zimmermann, Julia
Graf, Nicolas
Schilling, Christoph
Wilke, Hans-Joachim
Kienle, Annette - Abstract:
- Abstract: Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45 mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5 Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0 N shear force + 20.0 N per step, 51.0 N tension force + 10.2 N per step, 4.2 N m bending moment + 0.8 N m per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMDAbstract: Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45 mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5 Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0 N shear force + 20.0 N per step, 51.0 N tension force + 10.2 N per step, 4.2 N m bending moment + 0.8 N m per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0 mg/cc HA, pedicle width 9.8 ± 0.6 mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9–2.2 mm at 240 N shear force) were reproducible within the variation range of the in vitro experiments (0.6–3.5 mm at 240 N shear force). Screw loosening occurred continuously in each case between 140 N and 280 N, while abrupt failures of the specimen were observed only in vitro. In the mechanical testing model, no translational motion was detected in the screw entry point, while in vitro, translational motions of up to 2.5 mm in inferior direction were found, leading to a slight shift of the centre of rotation towards the screw tip. Translational motions of the screw tip of about 5 mm in superior direction were observed both in vitro and in the mechanical testing model, while they were continuous in the mechanical testing model and rapidly increasing after screw loosening initiation in vitro. The overall pedicle screw loosening characteristics were qualitatively and quantitatively similar between the mechanical testing model and the human vertebral specimens as long as there was no translation of the screw at the screw entrance point. Therefore, the novel mechanical testing model represents a promising method for the standardized testing of pedicle screws regarding screw loosening for cases where the screw rotates around a point close to the screw entry point. Graphical abstract: Highlights: A novel mechanical testing model for pedicle screw loosening was in vitro validated. PU foam and carbon fibre filled epoxy represent the cancellous bone and pedicle. Physiological cyclic loads were applied in the model and six human lumbar vertebrae. Translations of the model were within the variation range of the in vitro tests. The novel mechanical model is a valid method for standard testing of pedicle screws. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 77(2018)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 77(2018)
- Issue Display:
- Volume 77, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 77
- Issue:
- 2018
- Issue Sort Value:
- 2018-0077-2018-0000
- Page Start:
- 578
- Page End:
- 585
- Publication Date:
- 2018-01
- Subjects:
- Pedicle screw -- Mechanical testing model -- Validation -- PU foam -- In vitro experiment -- Physiological load application
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2017.10.030 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10762.xml