Measured and simulated thermal behaviour in rammed earth houses in a hot-arid climate. Part A: Structural behaviour. (January 2018)
- Record Type:
- Journal Article
- Title:
- Measured and simulated thermal behaviour in rammed earth houses in a hot-arid climate. Part A: Structural behaviour. (January 2018)
- Main Title:
- Measured and simulated thermal behaviour in rammed earth houses in a hot-arid climate. Part A: Structural behaviour
- Authors:
- Beckett, C.T.S.
Cardell-Oliver, R.
Ciancio, D.
Huebner, C. - Abstract:
- Abstract: Heating and cooling of residential buildings consumes around ten percent of the world's energy. One approach for reducing these costs is to exploit the high thermal mass of sustainable building materials, for example rammed earth (RE), for intelligent solar passive design. However, there is a lack of scientific evidence about the thermal performance of RE houses in real-world settings. This research investigated to what extent thermal performance in unconditioned RE structures in rural Australia can be captured by current accreditation software. Two custom-designed houses were built in the hot-arid city of Kalgoorlie-Boulder, Western Australia: one comprising traditional solid cement-stabilised rammed earth walls (RE) and the other walls with an insulating polystyrene core (iRE). Otherwise the houses were identical in orientation and design. The houses were instrumented to monitor indoor temperature and humidity conditions prior to and during occupancy. Results were compared to those simulated using cutting-edge assessment software BERS Pro (v4.3) as an example of that used for energy efficiency accreditation in Australia. This first paper in this series discusses the houses' construction and instrumentation and results obtained during the unoccupied period, i.e. those purely demonstrative of the structure's thermal performance. A second paper in the series presents data gathered during occupancy, to contrast occupant thermal comfort with that predictedAbstract: Heating and cooling of residential buildings consumes around ten percent of the world's energy. One approach for reducing these costs is to exploit the high thermal mass of sustainable building materials, for example rammed earth (RE), for intelligent solar passive design. However, there is a lack of scientific evidence about the thermal performance of RE houses in real-world settings. This research investigated to what extent thermal performance in unconditioned RE structures in rural Australia can be captured by current accreditation software. Two custom-designed houses were built in the hot-arid city of Kalgoorlie-Boulder, Western Australia: one comprising traditional solid cement-stabilised rammed earth walls (RE) and the other walls with an insulating polystyrene core (iRE). Otherwise the houses were identical in orientation and design. The houses were instrumented to monitor indoor temperature and humidity conditions prior to and during occupancy. Results were compared to those simulated using cutting-edge assessment software BERS Pro (v4.3) as an example of that used for energy efficiency accreditation in Australia. This first paper in this series discusses the houses' construction and instrumentation and results obtained during the unoccupied period, i.e. those purely demonstrative of the structure's thermal performance. A second paper in the series presents data gathered during occupancy, to contrast occupant thermal comfort with that predicted numerically. Measured data showed that both houses performed nominally-identically: the houses did not receive any relative benefit from including iRE. Simulated data was also similar per house. However, measured performance did not match that simulated: simulated rooms had poorer thermal stability and lag and, consequently, exaggerated internal temperature variations. Collected data has been made publicly available for future analyses. Abstract : Highlights: Two rammed earth houses were built in a hot-arid climate. One house had monolithic rammed earth walls and the other insulated walls. Performance was measured by sensors and modelled using state-of-the-art software. Incorporating costly insulation was shown to be not efficient for this climate. Simulations did not match predictions. Thermal stability in rooms with low thermal mass envelopes was significantly under-predicted. Thermal lag in rooms with high thermal mass envelopes was over-predicted. Data has been made publicly available for future analyses. … (more)
- Is Part Of:
- Journal of building engineering. Volume 15(2018)
- Journal:
- Journal of building engineering
- Issue:
- Volume 15(2018)
- Issue Display:
- Volume 15, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 15
- Issue:
- 2018
- Issue Sort Value:
- 2018-0015-2018-0000
- Page Start:
- 243
- Page End:
- 251
- Publication Date:
- 2018-01
- Subjects:
- Rammed earth -- Insulated rammed earth -- Thermal stability -- Thermal lag -- Environmental monitoring -- Rural housing
Building -- Periodicals
690.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23527102 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.jobe.2017.11.013 ↗
- Languages:
- English
- ISSNs:
- 2352-7102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10784.xml