Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair. (October 2017)
- Record Type:
- Journal Article
- Title:
- Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair. (October 2017)
- Main Title:
- Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair
- Authors:
- Deeken, Corey R.
Lake, Spencer P. - Abstract:
- Abstract: Abdominal wall hernias are one of the most common and long-standing surgical applications for biomaterials engineering. Yet, despite over 50 years of standard use of hernia repair materials, revision surgery is still required in nearly one third of patients due to hernia recurrence. To date, hernia mesh designs have focused on maximizing tensile strength to prevent structural failure of the implant. However, most recurrences occur at the biomaterial-tissue interface. There is a fundamental gap in understanding the degree to which a mechanical mismatch between hernia repair materials and host tissue contributes to failure at this interface. This review summarizes the current literature related to the anatomy and mechanics of both human and animal abdominal wall tissues, as well as the mechanical properties of many commonly-utilized hernia repair materials. The studies reviewed here reported greater compliance of the linea alba, larger strains for the intact abdominal wall, and greater stiffness for the rectus sheath and umbilical fascia when the tissues were loaded in the longitudinal direction compared to transverse. Additionally, greater stresses were observed in the linea alba when loaded in the transverse direction compared to longitudinal. Given these trends, a few recommendations can be made regarding orientation of mesh. The most compliant axis of the biomaterial should be oriented in the cranio-caudal (longitudinal) direction, and the strongest axis of theAbstract: Abdominal wall hernias are one of the most common and long-standing surgical applications for biomaterials engineering. Yet, despite over 50 years of standard use of hernia repair materials, revision surgery is still required in nearly one third of patients due to hernia recurrence. To date, hernia mesh designs have focused on maximizing tensile strength to prevent structural failure of the implant. However, most recurrences occur at the biomaterial-tissue interface. There is a fundamental gap in understanding the degree to which a mechanical mismatch between hernia repair materials and host tissue contributes to failure at this interface. This review summarizes the current literature related to the anatomy and mechanics of both human and animal abdominal wall tissues, as well as the mechanical properties of many commonly-utilized hernia repair materials. The studies reviewed here reported greater compliance of the linea alba, larger strains for the intact abdominal wall, and greater stiffness for the rectus sheath and umbilical fascia when the tissues were loaded in the longitudinal direction compared to transverse. Additionally, greater stresses were observed in the linea alba when loaded in the transverse direction compared to longitudinal. Given these trends, a few recommendations can be made regarding orientation of mesh. The most compliant axis of the biomaterial should be oriented in the cranio-caudal (longitudinal) direction, and the strongest axis of the biomaterial should be oriented in the medial-lateral (transverse) direction. The human abdominal wall is also anisotropic, with anisotropy ratios as high as 8–9 reported for the human linea alba. Current biomaterial designs exhibit anisotropy ratios in the range of 1–3, and it is unclear whether an ideal ratio exists for optimal match between mesh and tissue. This is likely dependent on implantation location as the linea alba, rectus sheath, and other tissues of the abdominal wall exhibit different characteristics. Given the number of unknowns yet to be addressed by studies of the human abdominal wall, it is unlikely that any single biomaterial design currently encompasses all of the ideal features identified. More data on the mechanical properties of the abdominal wall will be needed to establish a full set of guidelines for ideal mesh mechanics including strength, compliance, anisotropy, nonlinearity and hysteresis. Graphical abstract: Highlights: The human abdominal wall is a complex, heterogeneous, layered structure. Hernias disrupt the continuity of the abdominal wall and impair mechanical function. Hernia repair with biomaterials common; mechanical mismatch with tissue problematic The most compliant axis of the biomaterial should be oriented cranio-caudal. Need more data to define guidelines for ideal anisotropy, nonlinearity, hysteresis. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 74(2017)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 74(2017)
- Issue Display:
- Volume 74, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 74
- Issue:
- 2017
- Issue Sort Value:
- 2017-0074-2017-0000
- Page Start:
- 411
- Page End:
- 427
- Publication Date:
- 2017-10
- Subjects:
- Abdominal wall -- Anisotropy -- Biomaterials -- Hernia repair -- Mechanics -- Mesh
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2017.05.008 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10751.xml