Development of new method for D/H ratio measurements for volatile hydrocarbons of crude oils using solid phase micro-extraction (SPME) coupled to gas chromatography isotope ratio mass spectrometry (GC-IRMS). (January 2018)
- Record Type:
- Journal Article
- Title:
- Development of new method for D/H ratio measurements for volatile hydrocarbons of crude oils using solid phase micro-extraction (SPME) coupled to gas chromatography isotope ratio mass spectrometry (GC-IRMS). (January 2018)
- Main Title:
- Development of new method for D/H ratio measurements for volatile hydrocarbons of crude oils using solid phase micro-extraction (SPME) coupled to gas chromatography isotope ratio mass spectrometry (GC-IRMS)
- Authors:
- Li, Zhongping
Li, Liwu
Xing, Lantian
Liu, Yan
Zhang, Mingjie
Wang, Xibin
Cao, Chunhui
Wang, Zuodong - Abstract:
- Abstract: In compound-specific isotope analysis (CSIA), one major challenge is the effective sample treatment and the isolation of sufficient amount of analytes for accurate measurements for isotope ratios. The hydrogen isotope ratio (D/H) of normal level hydrocarbons in crude oils has been successfully used as an isotopic tracer in oil-oil and oil-gas correlations, but little progress so far has been made for small size hydrocarbons (C6 C15 ). In this paper, we presented a novel method for sample treatment and achieved the D/H ratio analysis for these particular compounds. The method can be characterized as an efficient approach featured by SPME (solid phase micro-extraction) coupled to GC-IRMS (gas chromatography-isotope ratio mass spectrometry). In this investigation, the CAR/DVB/PDMS fiber was evaluated and used as the absorptive material, and the operating conditions, including the extraction time (0.1 min–150 min) and the extraction temperature (−30 °C–140 °C), which may affect the adsorption amount, were carefully evaluated, and it was found that the adsorption yields varied considerably not only with the operating conditions but also with the molecular size. In addition, the possible hydrogen isotopic fractionation, which may exert strong influence on D/H ratios, were also discussed, it was found that the hydrogen isotopic fractionation were not observed in the extraction process, and the D/H ratios obtained via SPME-GC/IRMS were in good agreement with the EA-IRMS.Abstract: In compound-specific isotope analysis (CSIA), one major challenge is the effective sample treatment and the isolation of sufficient amount of analytes for accurate measurements for isotope ratios. The hydrogen isotope ratio (D/H) of normal level hydrocarbons in crude oils has been successfully used as an isotopic tracer in oil-oil and oil-gas correlations, but little progress so far has been made for small size hydrocarbons (C6 C15 ). In this paper, we presented a novel method for sample treatment and achieved the D/H ratio analysis for these particular compounds. The method can be characterized as an efficient approach featured by SPME (solid phase micro-extraction) coupled to GC-IRMS (gas chromatography-isotope ratio mass spectrometry). In this investigation, the CAR/DVB/PDMS fiber was evaluated and used as the absorptive material, and the operating conditions, including the extraction time (0.1 min–150 min) and the extraction temperature (−30 °C–140 °C), which may affect the adsorption amount, were carefully evaluated, and it was found that the adsorption yields varied considerably not only with the operating conditions but also with the molecular size. In addition, the possible hydrogen isotopic fractionation, which may exert strong influence on D/H ratios, were also discussed, it was found that the hydrogen isotopic fractionation were not observed in the extraction process, and the D/H ratios obtained via SPME-GC/IRMS were in good agreement with the EA-IRMS. Notably, the difference between the two approaches was generally within the expected uncertainties from 0.8‰ to 4.2‰, indicating the method is high efficient for volatile hydrocarbon enrichments and the D/H measurements. To assess the validity of the established method, one typical crude oil sample was analyzed, and the D/H ratio results displayed considerable large variation, enough to distinguished between different compounds, showing the established method is well suited for trace hydrocarbon enrichment, and provides so far the most efficient and reliable means for D/H analysis. Highlights: The hydrogen isotope fractionation was not observed. The D/H analytical errors range from 0.8‰ to 4.2‰. SPME-GC/IRMS is efficient for δD analysis of volatile hydrocarbons. … (more)
- Is Part Of:
- Marine and petroleum geology. Volume 89:Part 1(2018)
- Journal:
- Marine and petroleum geology
- Issue:
- Volume 89:Part 1(2018)
- Issue Display:
- Volume 89, Issue 1, Part 1 (2018)
- Year:
- 2018
- Volume:
- 89
- Issue:
- 1
- Part:
- 1
- Issue Sort Value:
- 2018-0089-0001-0001
- Page Start:
- 232
- Page End:
- 241
- Publication Date:
- 2018-01
- Subjects:
- Solid phase microextraction (SPME) -- Gas chromatography(GC) -- Hydrogen isotope ratio -- Isotope ratio mass-spectrometry(IRMS) -- Trace hydrocarbons -- Crude oils
Submarine geology -- Periodicals
Petroleum -- Geology -- Periodicals
Géologie sous-marine -- Périodiques
Pétrole -- Géologie -- Périodiques
Petroleum -- Geology
Submarine geology
Periodicals
Electronic journals
551.468 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02648172 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.marpetgeo.2017.01.008 ↗
- Languages:
- English
- ISSNs:
- 0264-8172
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5373.632100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10760.xml