Macular Vessel Density and Ganglion Cell/Inner Plexiform Layer Thickness and Their Combinational Index Using Artificial Intelligence. Issue 9 (September 2018)
- Record Type:
- Journal Article
- Title:
- Macular Vessel Density and Ganglion Cell/Inner Plexiform Layer Thickness and Their Combinational Index Using Artificial Intelligence. Issue 9 (September 2018)
- Main Title:
- Macular Vessel Density and Ganglion Cell/Inner Plexiform Layer Thickness and Their Combinational Index Using Artificial Intelligence
- Authors:
- Park, Keunheung
Kim, Jinmi
Lee, Jiwoong - Abstract:
- Abstract : Purpose: To evaluate the relationship between macular vessel density and ganglion cell to inner plexiform layer thickness (GCIPLT) and to compare their diagnostic performance. We attempted to develop a new combined parameter using an artificial neural network. Methods: A total of 173 subjects: 100 for the test and 73 for neural net training. The test group consisted of 32 healthy, 33 early, and 35 advanced glaucoma subjects. Macular GCIPLT and vessel density were measured using Spectralis optical coherence tomography and Topcon swept-source optical coherence tomography, respectively. Various regression models were used to investigate the relationships between macular vessel density and GCIPLT. A multilayer neural network with one hidden layer was used to determine a single combined parameter. To compare diagnostic performance, we used the area under the receiver operating characteristic curve (AUROC). Results: Correlation analyses in all subjects showed a significant correlation between macular vessel density and GCIPLT in all sectors ( r =0.27 to 0.56; all P s⩽0.006). The fitness of linear, quadratic, and exponential regression models showed clinically negligible differences (Akaike's information criterion=714.6, 713.8, and 713.3, respectively) and were almost linear. In differentiating normal and early glaucoma, the diagnostic power of macular GCIPLT (AUROC=0.67 to 0.81) was much better than that of macular vessel density (AUROC=0.50 to 0.60). However, whenAbstract : Purpose: To evaluate the relationship between macular vessel density and ganglion cell to inner plexiform layer thickness (GCIPLT) and to compare their diagnostic performance. We attempted to develop a new combined parameter using an artificial neural network. Methods: A total of 173 subjects: 100 for the test and 73 for neural net training. The test group consisted of 32 healthy, 33 early, and 35 advanced glaucoma subjects. Macular GCIPLT and vessel density were measured using Spectralis optical coherence tomography and Topcon swept-source optical coherence tomography, respectively. Various regression models were used to investigate the relationships between macular vessel density and GCIPLT. A multilayer neural network with one hidden layer was used to determine a single combined parameter. To compare diagnostic performance, we used the area under the receiver operating characteristic curve (AUROC). Results: Correlation analyses in all subjects showed a significant correlation between macular vessel density and GCIPLT in all sectors ( r =0.27 to 0.56; all P s⩽0.006). The fitness of linear, quadratic, and exponential regression models showed clinically negligible differences (Akaike's information criterion=714.6, 713.8, and 713.3, respectively) and were almost linear. In differentiating normal and early glaucoma, the diagnostic power of macular GCIPLT (AUROC=0.67 to 0.81) was much better than that of macular vessel density (AUROC=0.50 to 0.60). However, when vessel density information was incorporated into GCIPLT using the neural network, the combined parameter (AUROC=0.87) showed significantly enhanced diagnostic performance than all sectors of macular vessel density and GCIPLT (all P s⩽0.043). Conclusions: Macular vessel density was significantly decreased in glaucoma patients and showed an almost linear correlation with macular GCIPLT. The diagnostic performance of macular vessel density was much lower than that of macular GCIPLT. However, when incorporated into macular GCIPLT using an artificial neural network, the combined parameter showed better performance than macular GCIPLT alone. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 27:Issue 9(2018)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 27:Issue 9(2018)
- Issue Display:
- Volume 27, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 9
- Issue Sort Value:
- 2018-0027-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-09
- Subjects:
- vessel density -- GCIPL -- ganglion cell -- OCTA -- angiography -- neural network
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001028 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10761.xml