Unilateral and Bilateral Audiological Benefit With an Adhesively Attached, Noninvasive Bone Conduction Hearing System. Issue 8 (September 2018)
- Record Type:
- Journal Article
- Title:
- Unilateral and Bilateral Audiological Benefit With an Adhesively Attached, Noninvasive Bone Conduction Hearing System. Issue 8 (September 2018)
- Main Title:
- Unilateral and Bilateral Audiological Benefit With an Adhesively Attached, Noninvasive Bone Conduction Hearing System
- Authors:
- Gawliczek, Tom
Munzinger, Fabio
Anschuetz, Lukas
Caversaccio, Marco
Kompis, Martin
Wimmer, Wilhelm - Abstract:
- Abstract : Objective: To assess the audiological benefit of a noninvasive, adhesively attached bone conduction device (BCD1) in subjects with induced bilateral conductive hearing loss. Secondary objectives were to evaluate the additional benefit of bilateral fitting compared with unilateral fitting and to compare the outcomes with bone conduction devices attached to a softband (BCD2). Study Design: Prospective nonrandomized crossover study. Setting: Tertiary referral center. Patients: Fifteen subjects with induced bilateral conductive hearing loss. Main Outcome Measures: Sound field thresholds, speech understanding in quiet and in multinoise were assessed in unaided, unilateral, and bilateral treatment conditions. In addition, sound localization was evaluated in uni- and bilateral treatment conditions. Results: The outcomes of BCD1 and BCD2 were comparable. Sound field thresholds improved by 24.6 dB (BCD1) and 24.8 dB (BCD2) in the unilateral and 26.8 dB (BCD1) and 25.1 dB (BCD2) in the bilateral treatment condition. Speech reception thresholds (SRTs) in quiet improved by 20.0 dB (BCD1) and 21.7 dB (BCD2) in the unilateral and by 22.7 dB (BCD1) and 21.5 dB (BCD2) in the bilateral condition. If speech was presented from the front, SRTs in noise were improved by 3.6 dB and 4.2 dB (unilateral) and by 4.5 dB and 4.4 dB (bilateral) for BCD1 and BCD2, respectively. With speech presented from the unilateral side, SRTs were improved by 4.0 dB and 4.7 dB (unilateral) and 3.8 dB andAbstract : Objective: To assess the audiological benefit of a noninvasive, adhesively attached bone conduction device (BCD1) in subjects with induced bilateral conductive hearing loss. Secondary objectives were to evaluate the additional benefit of bilateral fitting compared with unilateral fitting and to compare the outcomes with bone conduction devices attached to a softband (BCD2). Study Design: Prospective nonrandomized crossover study. Setting: Tertiary referral center. Patients: Fifteen subjects with induced bilateral conductive hearing loss. Main Outcome Measures: Sound field thresholds, speech understanding in quiet and in multinoise were assessed in unaided, unilateral, and bilateral treatment conditions. In addition, sound localization was evaluated in uni- and bilateral treatment conditions. Results: The outcomes of BCD1 and BCD2 were comparable. Sound field thresholds improved by 24.6 dB (BCD1) and 24.8 dB (BCD2) in the unilateral and 26.8 dB (BCD1) and 25.1 dB (BCD2) in the bilateral treatment condition. Speech reception thresholds (SRTs) in quiet improved by 20.0 dB (BCD1) and 21.7 dB (BCD2) in the unilateral and by 22.7 dB (BCD1) and 21.5 dB (BCD2) in the bilateral condition. If speech was presented from the front, SRTs in noise were improved by 3.6 dB and 4.2 dB (unilateral) and by 4.5 dB and 4.4 dB (bilateral) for BCD1 and BCD2, respectively. With speech presented from the unilateral side, SRTs were improved by 4.0 dB and 4.7 dB (unilateral) and 3.8 dB and 4.8 dB (bilateral) compared with the unaided situation. If noise was presented from the contralateral side, small differences (−0.6 dB and −0.1 dB) were observed. Bilateral fitting brought additional benefits for speech understanding in noise and sound localization. Conclusions: Both bone conduction devices seem to be a valid treatment for patients with conductive hearing loss and minor sensorineural hearing loss component. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Otology & neurotology. Volume 39:Issue 8(2018)
- Journal:
- Otology & neurotology
- Issue:
- Volume 39:Issue 8(2018)
- Issue Display:
- Volume 39, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 39
- Issue:
- 8
- Issue Sort Value:
- 2018-0039-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-09
- Subjects:
- ADHEAR -- Baha -- Bilateral advantage -- Multinoise -- Softband -- Sound localization -- Speech reception in noise
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000001924 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10755.xml