Brief measurement of X-ray spectra using a lutetium-yttrium-oxyorthosilicate crystal and a micro-photomultiplier tube. (December 2017)
- Record Type:
- Journal Article
- Title:
- Brief measurement of X-ray spectra using a lutetium-yttrium-oxyorthosilicate crystal and a micro-photomultiplier tube. (December 2017)
- Main Title:
- Brief measurement of X-ray spectra using a lutetium-yttrium-oxyorthosilicate crystal and a micro-photomultiplier tube
- Authors:
- Sato, Eiichi
Oda, Yasuyuki
Ishii, Tomotaka
Hagiwara, Osahiko
Matsukiyo, Hiroshi
Enomoto, Toshiyuki
Watanabe, Manabu
Kusachi, Shinya - Abstract:
- Abstract: Brief measurement of X-ray spectra using a detector, consisting of an LYSO [Cerium doped Lutetium Yttrium Oxyorthosilicate, (Lu, Y)2 SiO5 :Ce] crystal and a μPMT (micro-photomultiplier tube) is described. X-ray photons are detected using the LYSO crystal and a 0.5-mm-diameter 3.0-mm-thick lead pinhole, and scintillation photons produced in the crystal are detected using the μPMT. The negative output voltages from the μPMT are input to a high-speed inverse-voltage-voltage amplifier, and the event pulses from the amplifier are sent to a multichannel analyzer to perform pulse-height analysis. Dark counts from the μPMT are not counted at all by increasing the time constant of the amplifier. Without the pinhole, the energy resolutions was approximately 40% at 59.5 keV. The photon energy was determined using two-point calibration using iodine-Kα fluorescence and tungsten Kα-photons from an X-ray-tube target. At a tube voltage of 100 kV, the maximum tube current without event-pulse pileups was 0.24 mA. Using the LYSO-μPMT detector, both the maximum and maximum-count energies increased with increasing tube voltage, and the maximum count rate was 72 kilocounts per second at a tube voltage of 100 kV and a current of 0.24 mA. Dual-energy computed tomography utilizing K- and L-edges was accomplished using gadolinium contrast media. Highlights: X-ray spectra were measured using LYSO-μPMT detector and pinhole. High-speed inverse amplifier for μPMT has been developed. Zero darkAbstract: Brief measurement of X-ray spectra using a detector, consisting of an LYSO [Cerium doped Lutetium Yttrium Oxyorthosilicate, (Lu, Y)2 SiO5 :Ce] crystal and a μPMT (micro-photomultiplier tube) is described. X-ray photons are detected using the LYSO crystal and a 0.5-mm-diameter 3.0-mm-thick lead pinhole, and scintillation photons produced in the crystal are detected using the μPMT. The negative output voltages from the μPMT are input to a high-speed inverse-voltage-voltage amplifier, and the event pulses from the amplifier are sent to a multichannel analyzer to perform pulse-height analysis. Dark counts from the μPMT are not counted at all by increasing the time constant of the amplifier. Without the pinhole, the energy resolutions was approximately 40% at 59.5 keV. The photon energy was determined using two-point calibration using iodine-Kα fluorescence and tungsten Kα-photons from an X-ray-tube target. At a tube voltage of 100 kV, the maximum tube current without event-pulse pileups was 0.24 mA. Using the LYSO-μPMT detector, both the maximum and maximum-count energies increased with increasing tube voltage, and the maximum count rate was 72 kilocounts per second at a tube voltage of 100 kV and a current of 0.24 mA. Dual-energy computed tomography utilizing K- and L-edges was accomplished using gadolinium contrast media. Highlights: X-ray spectra were measured using LYSO-μPMT detector and pinhole. High-speed inverse amplifier for μPMT has been developed. Zero dark counting was carried out to detect low-energy photons. Energy calibration was performed using Kα photons of iodine and tungsten. L- and K-edge CT was accomplished simultaneously using Gd media. … (more)
- Is Part Of:
- Radiation measurements. Volume 107(2017:Dec.)
- Journal:
- Radiation measurements
- Issue:
- Volume 107(2017:Dec.)
- Issue Display:
- Volume 107 (2017)
- Year:
- 2017
- Volume:
- 107
- Issue Sort Value:
- 2017-0107-0000-0000
- Page Start:
- 94
- Page End:
- 101
- Publication Date:
- 2017-12
- Subjects:
- X-ray spectra -- LYSO-μPMT detector -- High-speed amplifier -- Zero dark counting -- Brief energy calibration -- Absorption-edge CT
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2017.09.007 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10742.xml