Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial. (1st September 2019)
- Record Type:
- Journal Article
- Title:
- Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial. (1st September 2019)
- Main Title:
- Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus
- Authors:
- Paradies, Valeria
Vlachojannis, Georgios J.
Royaards, Kees-Jan
Wassing, Jochem
van der Ent, Martin
Smits, Pieter C. - Abstract:
- Abstract: Background: Drug eluting stents with biodegradable polymers have been developed to address the risk of very late adverse events. Long-term comparison data between the biodegradable polymer-coated biolimus-eluting stent (BES; Nobori®) and the second-generation durable polymer-coated everolimus-eluting stent (EES; XIENCE V® or XIENCE PRIME® or PROMUS™) in diabetic patients are scarce. Methods: The COMPARE II trial was an investigator-initiated, multicenter, open-label, randomized, all-comers trial which assigned patients undergoing percutaneous coronary intervention (PCI) in a 2:1 fashion to either BES or EES. We analyzed the safety and efficacy outcomes in diabetic patients at 5 year follow-up. The primary pre-specified composite endpoint major adverse cardiac event (MACE) was defined as cardiac death, non-fatal target-vessel myocardial infarction (TV-MI), or clinically indicated target vessel revascularization (CD-TVR). Results: Out of 2707 study patients, 588 were diabetics (21.7%) of whom 391 were treated with BES and 197 with EES. At 5 years follow-up, MACE occurred in 87 patients (22.2%) in the BES group and in 34 patients (17.2%) in the EES group ( p = .34). Other safety and efficacy endpoints did not differ between stent groups. Conclusions: At 5 years follow-up, no differences in terms of MACE as well as all analyzed safety and efficacy measures, including stent thrombosis, between the biodegradable polymer-coated BES and the durable polymer-coated EES inAbstract: Background: Drug eluting stents with biodegradable polymers have been developed to address the risk of very late adverse events. Long-term comparison data between the biodegradable polymer-coated biolimus-eluting stent (BES; Nobori®) and the second-generation durable polymer-coated everolimus-eluting stent (EES; XIENCE V® or XIENCE PRIME® or PROMUS™) in diabetic patients are scarce. Methods: The COMPARE II trial was an investigator-initiated, multicenter, open-label, randomized, all-comers trial which assigned patients undergoing percutaneous coronary intervention (PCI) in a 2:1 fashion to either BES or EES. We analyzed the safety and efficacy outcomes in diabetic patients at 5 year follow-up. The primary pre-specified composite endpoint major adverse cardiac event (MACE) was defined as cardiac death, non-fatal target-vessel myocardial infarction (TV-MI), or clinically indicated target vessel revascularization (CD-TVR). Results: Out of 2707 study patients, 588 were diabetics (21.7%) of whom 391 were treated with BES and 197 with EES. At 5 years follow-up, MACE occurred in 87 patients (22.2%) in the BES group and in 34 patients (17.2%) in the EES group ( p = .34). Other safety and efficacy endpoints did not differ between stent groups. Conclusions: At 5 years follow-up, no differences in terms of MACE as well as all analyzed safety and efficacy measures, including stent thrombosis, between the biodegradable polymer-coated BES and the durable polymer-coated EES in diabetic patients were observed. Highlights: DM continues to negatively impact on the performance of new-generation DES. Higher rates of adverse events are reported in diabetic patients. No difference in terms of MACE and TLF were detected between BES and EES groups. … (more)
- Is Part Of:
- International journal of cardiology. Volume 290(2019)
- Journal:
- International journal of cardiology
- Issue:
- Volume 290(2019)
- Issue Display:
- Volume 290, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 290
- Issue:
- 2019
- Issue Sort Value:
- 2019-0290-2019-0000
- Page Start:
- 40
- Page End:
- 44
- Publication Date:
- 2019-09-01
- Subjects:
- Biodegradable polymer -- Diabetes mellitus -- Drug eluting stents
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2019.04.054 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10742.xml