Comparison of different locking plate fixation methods in lateral malleolus fractures. Issue 3 (June 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of different locking plate fixation methods in lateral malleolus fractures. Issue 3 (June 2019)
- Main Title:
- Comparison of different locking plate fixation methods in lateral malleolus fractures
- Authors:
- Bilgetekin, Yenel Gürkan
Çatma, Mehmet Faruk
Öztürk, Alper
Ünlü, Serhan
Ersan, Önder - Abstract:
- Highlights: One-third tubular and anatomic locking plates have similar clinical and radiological outcomes for treatment of lateral malleolar fractures. Distal anatomic locking plates allows more distal screws which can be considered when treating more distal fractures. One-third tubular locking plates reduce treatment cost so anatomical plates can be reserved for exact indications. Abstract: Background: Several fixation methods may be used for displaced lateral malleolar fractures. We aimed to compare clinical and radiologic outcomes associated with use of locking one third tubular plate vs. anatomical distal fibula locking plate in lateral malleolar fractures. Methods: A total of 62 orthopedic patients operated for lateral malleolus fracture were included in this retrospective study. Patients were divided into two groups regarding the plate used for fixation as locking one third tubular plate (group I; n = 37) and locking anatomical distal fibula plate (group II; n = 25). Data on Danis–Weber ankle fracture classification (Type A, Type B), duration of follow up, clinical outcome [ankle range of motion (ROM), American Orthopaedic Foot & Ankle Society (AOFAS) score], radiological outcomes (adequacy of reduction, loss of alignment), time to fracture healing and complications were recorded in study groups. Results: No significant difference was noted between groups in terms of AOFAS score [87.0 (73–100) vs. 85.0 (71–100), respectively (p = 0.339)] and no patients had severeHighlights: One-third tubular and anatomic locking plates have similar clinical and radiological outcomes for treatment of lateral malleolar fractures. Distal anatomic locking plates allows more distal screws which can be considered when treating more distal fractures. One-third tubular locking plates reduce treatment cost so anatomical plates can be reserved for exact indications. Abstract: Background: Several fixation methods may be used for displaced lateral malleolar fractures. We aimed to compare clinical and radiologic outcomes associated with use of locking one third tubular plate vs. anatomical distal fibula locking plate in lateral malleolar fractures. Methods: A total of 62 orthopedic patients operated for lateral malleolus fracture were included in this retrospective study. Patients were divided into two groups regarding the plate used for fixation as locking one third tubular plate (group I; n = 37) and locking anatomical distal fibula plate (group II; n = 25). Data on Danis–Weber ankle fracture classification (Type A, Type B), duration of follow up, clinical outcome [ankle range of motion (ROM), American Orthopaedic Foot & Ankle Society (AOFAS) score], radiological outcomes (adequacy of reduction, loss of alignment), time to fracture healing and complications were recorded in study groups. Results: No significant difference was noted between groups in terms of AOFAS score [87.0 (73–100) vs. 85.0 (71–100), respectively (p = 0.339)] and no patients had severe restriction in sagittal and hindfoot motion in both groups. The two groups showed similar healing time [9.0 (7–13) weeks vs. 10.0 (8–13) weeks, respectively (p = 0.355)] and complication rate [0.0% vs. 4.0%, respectively (p = 0.403)]. Conclusions: This study revealed no significant difference between use of locking one third tubular plate and locking anatomical distal fibula plate in lateral malleolar fixation, in terms of clinical and radiological outcomes, complication rates and fracture healing time. … (more)
- Is Part Of:
- Foot and ankle surgery. Volume 25:Issue 3(2019)
- Journal:
- Foot and ankle surgery
- Issue:
- Volume 25:Issue 3(2019)
- Issue Display:
- Volume 25, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2019-0025-0003-0000
- Page Start:
- 366
- Page End:
- 370
- Publication Date:
- 2019-06
- Subjects:
- Ankle fracture -- Distal fibula -- Locking plate -- Lateral malleolar fixation -- Long-term outcomes
Foot -- Surgery -- Periodicals
Ankle -- Surgery -- Periodicals
Ankle -- surgery -- Periodicals
Foot -- surgery -- Periodicals
Ankle -- Surgery
Foot -- Surgery
Periodicals
Electronic journals
617.58 - Journal URLs:
- http://www.sciencedirect.com/science/journal/12687731 ↗
http://www3.interscience.wiley.com/journal/119485132/home ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1268-7731;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1460-9584 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/12687731 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/12687731 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.fas.2018.01.004 ↗
- Languages:
- English
- ISSNs:
- 1268-7731
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3984.875000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10745.xml