Haemodynamic effects of incomplete stent apposition in curved coronary arteries. (3rd October 2017)
- Record Type:
- Journal Article
- Title:
- Haemodynamic effects of incomplete stent apposition in curved coronary arteries. (3rd October 2017)
- Main Title:
- Haemodynamic effects of incomplete stent apposition in curved coronary arteries
- Authors:
- Chen, Winson X.
Poon, Eric K.W.
Thondapu, Vikas
Hutchins, Nicholas
Barlis, Peter
Ooi, Andrew - Abstract:
- Abstract: Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, as a result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near-wall laminar blood flow and form a micro-recirculation environment. The micro-recirculation environment is often associated with low wall shear stress (WSS) and upsets the delicate balance of vascular biology, providing possible nidus for thrombosis and restenosis. In this study, a three-dimensional (3D) stent model was virtually deployed into an idealised curved coronary artery. Computational fluid dynamics (CFD) simulations were carried out to systematically analyse the haemodynamic effects of increasing maximum ISA distances, ranging from 180 (moderate), 400 (intermediate) to 910 μ m (severe) in an artery with decreasing radius of curvature (ROC). Micro-recirculations around both proximal and distal malapposed struts become more pronounced as compared to fully-apposed struts. The accompanying areas of low temporally-averaged WSS (AL-TAWSS) can increase twofold compared to the fully-apposed condition. Furthermore, substantial regions (∼5.2% and 9.0%) of AL-TAWSS are detached from the distal end of the malapposed struts in both moderate and intermediate cases respectively. Malapposed stents also induce more variation of TAWSS at the inner bend ofAbstract: Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, as a result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near-wall laminar blood flow and form a micro-recirculation environment. The micro-recirculation environment is often associated with low wall shear stress (WSS) and upsets the delicate balance of vascular biology, providing possible nidus for thrombosis and restenosis. In this study, a three-dimensional (3D) stent model was virtually deployed into an idealised curved coronary artery. Computational fluid dynamics (CFD) simulations were carried out to systematically analyse the haemodynamic effects of increasing maximum ISA distances, ranging from 180 (moderate), 400 (intermediate) to 910 μ m (severe) in an artery with decreasing radius of curvature (ROC). Micro-recirculations around both proximal and distal malapposed struts become more pronounced as compared to fully-apposed struts. The accompanying areas of low temporally-averaged WSS (AL-TAWSS) can increase twofold compared to the fully-apposed condition. Furthermore, substantial regions (∼5.2% and 9.0%) of AL-TAWSS are detached from the distal end of the malapposed struts in both moderate and intermediate cases respectively. Malapposed stents also induce more variation of TAWSS at the inner bend of the artery. At the stent surface, maximum WSS increases threefold from the fully-apposed case to intermediate ISA. High WSS on the strut surface is known to activate platelets which when exposed to the micro-recirculation environment may lead to their deposition and thrombosis. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 63(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 63(2017)
- Issue Display:
- Volume 63, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 63
- Issue:
- 2017
- Issue Sort Value:
- 2017-0063-2017-0000
- Page Start:
- 164
- Page End:
- 173
- Publication Date:
- 2017-10-03
- Subjects:
- Computational fluid dynamics -- Malapposition -- Curved arteries -- Haemodynamics -- Coronary stent
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.09.016 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10729.xml