Dynamic digital tomosynthesis-radiculography is useful for diagnosis of lumbar foraminal stenosis at an adjacent level after lumbar fusion surgery: A case report. (July 2019)
- Record Type:
- Journal Article
- Title:
- Dynamic digital tomosynthesis-radiculography is useful for diagnosis of lumbar foraminal stenosis at an adjacent level after lumbar fusion surgery: A case report. (July 2019)
- Main Title:
- Dynamic digital tomosynthesis-radiculography is useful for diagnosis of lumbar foraminal stenosis at an adjacent level after lumbar fusion surgery: A case report
- Authors:
- Mataki, Kentaro
Koda, Masao
Miura, Kousei
Shibao, Yosuke
Kumagai, Hiroshi
Nagashima, Katsuya
Noguchi, Hiroshi
Funayama, Toru
Abe, Tetsuya
Yamazaki, Masashi - Abstract:
- Highlights: A case of L5 radiculopathy nearby an implant occurred after L3–L5 fusion surgery. The nerve root nearby implants was not depicted in MRI because of artifacts. Digital tomosynthesis can acquire images with reduced metallic related artifacts. Digital tomosynthesis can acquire radiculography images in an upright position. Digital tomosynthesis is useful for diagnosing radiculopathy nearby implants. Abstract: After spine fusion surgery, it is difficult to evaluate the spinal canal and nerve roots using magnetic resonance imaging (MRI) because of metallic implant-related artifacts. Digital tomosynthesis is a new radiographic technique that can acquire tomographic images with reduced metallic artifact effects compared with MRI. We report a case demonstrating the visualization of nerve roots nearby metallic implants using dynamic tomosynthesis-radiculography (DTRG) after spinal fusion surgery. A 77-year-old man, who 3 years earlier underwent spine fusion surgery at L3–L5, presented complaining of newly-onset low back pain and radicular symptoms in the right fifth lumbar (L5) nerve root area. His symptoms were exacerbated when he stood upright. We suspected right L5 nerve root radiculopathy, but MRI could not depict any lesion of the nerve root because of metallic implant-related artifacts. We performed DTRG at the right L5 nerve root with the patient in both prone and upright positions. The right L5 nerve root was detected clearly, and nerve root compression at theHighlights: A case of L5 radiculopathy nearby an implant occurred after L3–L5 fusion surgery. The nerve root nearby implants was not depicted in MRI because of artifacts. Digital tomosynthesis can acquire images with reduced metallic related artifacts. Digital tomosynthesis can acquire radiculography images in an upright position. Digital tomosynthesis is useful for diagnosing radiculopathy nearby implants. Abstract: After spine fusion surgery, it is difficult to evaluate the spinal canal and nerve roots using magnetic resonance imaging (MRI) because of metallic implant-related artifacts. Digital tomosynthesis is a new radiographic technique that can acquire tomographic images with reduced metallic artifact effects compared with MRI. We report a case demonstrating the visualization of nerve roots nearby metallic implants using dynamic tomosynthesis-radiculography (DTRG) after spinal fusion surgery. A 77-year-old man, who 3 years earlier underwent spine fusion surgery at L3–L5, presented complaining of newly-onset low back pain and radicular symptoms in the right fifth lumbar (L5) nerve root area. His symptoms were exacerbated when he stood upright. We suspected right L5 nerve root radiculopathy, but MRI could not depict any lesion of the nerve root because of metallic implant-related artifacts. We performed DTRG at the right L5 nerve root with the patient in both prone and upright positions. The right L5 nerve root was detected clearly, and nerve root compression at the foramina when the patient was upright was exacerbated more than when the patient was in a prone position. DTRG is helpful to diagnose lumbar foraminal stenosis nearby metallic implants after spine fusion surgery. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 65(2019)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 65(2019)
- Issue Display:
- Volume 65, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 65
- Issue:
- 2019
- Issue Sort Value:
- 2019-0065-2019-0000
- Page Start:
- 148
- Page End:
- 150
- Publication Date:
- 2019-07
- Subjects:
- Digital tomosynthesis -- Visualization of nerve root -- Metallic artifact
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2019.03.065 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10694.xml