Outcomes after heart transplantation in sensitized patients bridged with ventricular assist devices. Issue 6 (2nd May 2019)
- Record Type:
- Journal Article
- Title:
- Outcomes after heart transplantation in sensitized patients bridged with ventricular assist devices. Issue 6 (2nd May 2019)
- Main Title:
- Outcomes after heart transplantation in sensitized patients bridged with ventricular assist devices
- Authors:
- Fraser, Charles D.
Zhou, Xun
Magruder, J. Trent
Suarez‐Pierre, Alejandro
Lui, Cecillia
Grimm, Joshua C.
Higgins, Robert
Kilic, Ahmet - Abstract:
- Abstract: Objective: Sensitization has been associated with worse outcomes following heart transplantation (HTx). The use of ventricular assist devices (VAD) is a risk factor for the development of sensitization. We investigated the impact of left ventricular assist devices (LVAD) and sensitization in HTx recipients. Methods: We queried the UNOS database for all heart transplants performed from January 2000 through December 2016. Patients were considered highly sensitized and included if panel‐reactive antibody (PRA) activity was 25% or higher. Patients were separated by pretransplant LVAD utilization and subgroup analysis was performed by device type (HeartMate II or HeartWare). Outcomes included Kaplan‐Meier survival and episodes of rejection within 1 year of HTx. Results: Of 18 009 recipients, 2434 (14%) were highly sensitized. 1055 (43.3%) were bridged with a VAD. In multivariate analysis, LVAD use did not impact 1‐year (hazards ratio [HR], 1.30; P = 0.052) or 5‐year survival (HR, 1.18; P = 0.112) in highly sensitized recipients. Furthermore, episodes of rejection were not affected by LVAD status ( P = 0.765). Of the 1055 sensitized LVAD‐bridged transplant recipients, 624 (59%) were implanted with a HeartMate II and 99 (9.4%) were bridged with a HeartWare device. In multivariate analysis, no differences were observed in 1‐year survival (HR, 0.86; P = 0.664), 5‐year survival (HR, 1.35; P = 0.209), or episodes of rejection ( P = 0.497). Conclusions: The use ofAbstract: Objective: Sensitization has been associated with worse outcomes following heart transplantation (HTx). The use of ventricular assist devices (VAD) is a risk factor for the development of sensitization. We investigated the impact of left ventricular assist devices (LVAD) and sensitization in HTx recipients. Methods: We queried the UNOS database for all heart transplants performed from January 2000 through December 2016. Patients were considered highly sensitized and included if panel‐reactive antibody (PRA) activity was 25% or higher. Patients were separated by pretransplant LVAD utilization and subgroup analysis was performed by device type (HeartMate II or HeartWare). Outcomes included Kaplan‐Meier survival and episodes of rejection within 1 year of HTx. Results: Of 18 009 recipients, 2434 (14%) were highly sensitized. 1055 (43.3%) were bridged with a VAD. In multivariate analysis, LVAD use did not impact 1‐year (hazards ratio [HR], 1.30; P = 0.052) or 5‐year survival (HR, 1.18; P = 0.112) in highly sensitized recipients. Furthermore, episodes of rejection were not affected by LVAD status ( P = 0.765). Of the 1055 sensitized LVAD‐bridged transplant recipients, 624 (59%) were implanted with a HeartMate II and 99 (9.4%) were bridged with a HeartWare device. In multivariate analysis, no differences were observed in 1‐year survival (HR, 0.86; P = 0.664), 5‐year survival (HR, 1.35; P = 0.209), or episodes of rejection ( P = 0.497). Conclusions: The use of ventricular assist devices did not impact survival or rejection within 1 year of HTx in highly sensitized patients. Highly sensitized recipients have similar outcomes regardless of prior LVAD support or type of LVAD used as a bridge to transplantation. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 34:Issue 6(2019)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 34:Issue 6(2019)
- Issue Display:
- Volume 34, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 6
- Issue Sort Value:
- 2019-0034-0006-0000
- Page Start:
- 474
- Page End:
- 481
- Publication Date:
- 2019-05-02
- Subjects:
- heart transplantation -- panel‐reactive antibody -- sensitization
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.14066 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10705.xml