Renal function and the long‐term clinical outcomes of cardiac resynchronization therapy with or without defibrillation. Issue 6 (3rd April 2019)
- Record Type:
- Journal Article
- Title:
- Renal function and the long‐term clinical outcomes of cardiac resynchronization therapy with or without defibrillation. Issue 6 (3rd April 2019)
- Main Title:
- Renal function and the long‐term clinical outcomes of cardiac resynchronization therapy with or without defibrillation
- Authors:
- Leyva, Francisco
Zegard, Abbasin
Taylor, Robin
Foley, Paul W.X.
Umar, Fraz
Patel, Kiran
Panting, Jonathan
Ferro, Charles J.
Chalil, Shajil
Marshall, Howard
Qiu, Tian - Abstract:
- Abstract: Background and Aims: Patients with moderate‐to‐severe chronic kidney disease (CKD) are underrepresented in clinical trials of cardiac resynchronization therapy (CRT)‐defibrillation (CRT‐D) or CRT‐pacing (CRT‐P). We sought to determine whether outcomes after CRT‐D are better than after CRT‐P over a wide spectrum of CKD. Methods and Results: Clinical events were quantified in relation to preimplant estimated glomerular filtration rate (eGFR) after CRT‐D (n = 410 [39.2%]) or CRT‐P (n = 636 [60.8%]) implantation. Over a follow‐up period of 3.7 years (median, interquartile range: 2.1–5.7), the eGFR < 60 group (n = 598) had a higher risk of total mortality (adjusted hazard ratio [aHR]: 1.28; P = 0.017), total mortality or heart failure (HF) hospitalization (aHR: 1.32; P = 0.004), total mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.34; P = 0.002), and cardiac mortality (aHR: 1.33; P = 0.036), compared to the eGFR ≥ 60 group (n = 448), after covariate adjustment. In analyses of CRT‐D versus CRT‐P, CRT‐D was associated with a lower risk of total mortality (eGFR ≥ 60 HR: 0.65; P = 0.028; eGFR < 60 HR: 0.64, P = 0.002), total mortality or HF hospitalization (eGFR ≥ 60 aHR: 0.66; P = 0.021; eGFR < 60 aHR: 0.69, P = 0.007), total mortality or hospitalization for MACEs (eGFR ≥ 60 aHR: 0.70; P = 0.039; eGFR < 60 aHR: 0.69, P = 0.005), and cardiac mortality (eGFR ≥ 60 aHR: 0.60; P = 0.026; eGFR < 60 aHR: 0.55; P = 0.003). Conclusion: In CRTAbstract: Background and Aims: Patients with moderate‐to‐severe chronic kidney disease (CKD) are underrepresented in clinical trials of cardiac resynchronization therapy (CRT)‐defibrillation (CRT‐D) or CRT‐pacing (CRT‐P). We sought to determine whether outcomes after CRT‐D are better than after CRT‐P over a wide spectrum of CKD. Methods and Results: Clinical events were quantified in relation to preimplant estimated glomerular filtration rate (eGFR) after CRT‐D (n = 410 [39.2%]) or CRT‐P (n = 636 [60.8%]) implantation. Over a follow‐up period of 3.7 years (median, interquartile range: 2.1–5.7), the eGFR < 60 group (n = 598) had a higher risk of total mortality (adjusted hazard ratio [aHR]: 1.28; P = 0.017), total mortality or heart failure (HF) hospitalization (aHR: 1.32; P = 0.004), total mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.34; P = 0.002), and cardiac mortality (aHR: 1.33; P = 0.036), compared to the eGFR ≥ 60 group (n = 448), after covariate adjustment. In analyses of CRT‐D versus CRT‐P, CRT‐D was associated with a lower risk of total mortality (eGFR ≥ 60 HR: 0.65; P = 0.028; eGFR < 60 HR: 0.64, P = 0.002), total mortality or HF hospitalization (eGFR ≥ 60 aHR: 0.66; P = 0.021; eGFR < 60 aHR: 0.69, P = 0.007), total mortality or hospitalization for MACEs (eGFR ≥ 60 aHR: 0.70; P = 0.039; eGFR < 60 aHR: 0.69, P = 0.005), and cardiac mortality (eGFR ≥ 60 aHR: 0.60; P = 0.026; eGFR < 60 aHR: 0.55; P = 0.003). Conclusion: In CRT recipients, moderate CKD is associated with a higher mortality and morbidity compared to normal renal function or mild CKD. Despite less favorable absolute outcomes, patients with moderate CKD had better outcomes after CRT‐D than after CRT‐P. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 6(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 6(2019)
- Issue Display:
- Volume 42, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2019-0042-0006-0000
- Page Start:
- 595
- Page End:
- 602
- Publication Date:
- 2019-04-03
- Subjects:
- cardiac resynchronization therapy -- chronic kidney disease -- heart failure -- implantable cardioverter defibrillator
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13659 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10687.xml