Accuracy of the interferon-γ release assay for the diagnosis of active tuberculosis among HIV-seropositive individuals: a systematic review and meta-analysis. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Accuracy of the interferon-γ release assay for the diagnosis of active tuberculosis among HIV-seropositive individuals: a systematic review and meta-analysis. Issue 1 (December 2016)
- Main Title:
- Accuracy of the interferon-γ release assay for the diagnosis of active tuberculosis among HIV-seropositive individuals: a systematic review and meta-analysis
- Authors:
- Huo, Zhen-yu
Peng, Li - Abstract:
- Abstract Background Although the interferon-γ release assay (IGRA) has become a widely accepted means for the diagnosis of latent tuberculosis infection (LTBI), the role of the IGRA in diagnosing active tuberculosis (ATB) among human immunodeficiency virus (HIV)-seropositive individuals remains controversial. Previous analyses did not set up rational inclusive criteria for screening articles with strict control groups and a gold standard for ATB diagnosis. Therefore, we conducted a systematic review of the latest evidence to evaluate the accuracy of IGRA for HIV-seropositive patients. Methods Initially, we searched the EMBASE, Cochrane and MEDLINE databases to find research articles published from January 2000 to October 2015 that used the QuantiFERON-TB Gold In-Tube assay (QFT-IT) or the T-SPOT.TB assay (T-SPOT) to diagnose ATB among HIV-seropositive individuals. We separately calculated the pooled sensitivity, specificity, and proportion of indeterminate events and then summarized the results using forest plots to estimate the accuracy of the QFT-IT and T-SPOT assays. Results A total of 1, 743 studies were discovered after searching; 11 studies met our selection standards and were included for meta-analysis. The pooled sensitivity and specificity of the QFT-IT assay were 69 % (95 % CI, 50–84 %, I2 = 85.22 %) and 76 % (95 % CI, 53–90 %, I2 = 98.16 %), respectively, and the optimum area under the curve (AUC) was 0.78 (95 % CI, 0.74–0.82). The pooled sensitivity andAbstract Background Although the interferon-γ release assay (IGRA) has become a widely accepted means for the diagnosis of latent tuberculosis infection (LTBI), the role of the IGRA in diagnosing active tuberculosis (ATB) among human immunodeficiency virus (HIV)-seropositive individuals remains controversial. Previous analyses did not set up rational inclusive criteria for screening articles with strict control groups and a gold standard for ATB diagnosis. Therefore, we conducted a systematic review of the latest evidence to evaluate the accuracy of IGRA for HIV-seropositive patients. Methods Initially, we searched the EMBASE, Cochrane and MEDLINE databases to find research articles published from January 2000 to October 2015 that used the QuantiFERON-TB Gold In-Tube assay (QFT-IT) or the T-SPOT.TB assay (T-SPOT) to diagnose ATB among HIV-seropositive individuals. We separately calculated the pooled sensitivity, specificity, and proportion of indeterminate events and then summarized the results using forest plots to estimate the accuracy of the QFT-IT and T-SPOT assays. Results A total of 1, 743 studies were discovered after searching; 11 studies met our selection standards and were included for meta-analysis. The pooled sensitivity and specificity of the QFT-IT assay were 69 % (95 % CI, 50–84 %, I2 = 85.22 %) and 76 % (95 % CI, 53–90 %, I2 = 98.16 %), respectively, and the optimum area under the curve (AUC) was 0.78 (95 % CI, 0.74–0.82). The pooled sensitivity and specificity of the T-SPOT assay were 89 % (95 % CI, 66–97 %, I2 = 94.48 %) and 87 % (95 % CI, 38–99 %, I2 = 97.92 %), respectively, and the AUC was 0.93 (95 % CI, 0.90–0.95). The pooled ratios of the indeterminate results of the QFT-IT and T-SPOT assays were 0.07 (95 % CI, 0.06–0.09, I2 = 74.8 %) and 0.19 (95 % CI, 0.15–0.24, I2 = 88.3 %), respectively, calculated using the fixed effect model, and 0.08 (95 % CI, 0.06–0.12, I2 = 74.8 %) and 0.10 (95 % CI, 0.03–0.25, I2 = 88.3 %), respectively, calculated using the random effects model. Conclusions The IGRA does not appear to be optimal for the clinical confirmation of ATB cases in HIV-seropositive patients; however, the T-SPOT assay may have greater accuracy in distinguishing ATB cases among HIV-infected individuals than the QFT-IT assay, while the QFT-IT assay appears to reduce the occurrence of indeterminate results. Furthermore, modification and additional trial designs are required to improve diagnostic effectiveness. … (more)
- Is Part Of:
- BMC infectious diseases. Volume 16:Issue 1(2016)
- Journal:
- BMC infectious diseases
- Issue:
- Volume 16:Issue 1(2016)
- Issue Display:
- Volume 16, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2016-0016-0001-0000
- Page Start:
- 1
- Page End:
- 11
- Publication Date:
- 2016-12
- Subjects:
- Diagnostic accuracy -- Interferon-γ release assay -- Active tuberculosis -- HIV-seropositive individuals -- Systematic review
Communicable diseases -- Periodicals
Sexually Transmitted Diseases -- Periodicals
616.905 - Journal URLs:
- http://www.biomedcentral.com/bmcinfectdis/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=36 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12879-016-1687-8 ↗
- Languages:
- English
- ISSNs:
- 1471-2334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10683.xml