Detection of squamous cell carcinoma antigen in cervical cancer by surface-enhanced Raman scattering-based immunoassay. Issue 21 (21st May 2019)
- Record Type:
- Journal Article
- Title:
- Detection of squamous cell carcinoma antigen in cervical cancer by surface-enhanced Raman scattering-based immunoassay. Issue 21 (21st May 2019)
- Main Title:
- Detection of squamous cell carcinoma antigen in cervical cancer by surface-enhanced Raman scattering-based immunoassay
- Authors:
- Lu, Dan
Xia, Ji
Deng, Zhuo
Cao, Xiaowei - Abstract:
- Abstract : In this study, a highly specific, sensitive and reliable immunosensor has been developed for the quantitative detection of the squamous cell carcinoma antigen (SCCA) in cervical cancer, based on surface-enhanced Raman scattering (SERS). Abstract : In this study, a highly specific, sensitive and reliable immunosensor has been developed for the quantitative detection of the squamous cell carcinoma antigen (SCCA) in cervical cancer, based on surface-enhanced Raman scattering (SERS). The gold nanoparticle-coated polydopamine resin microspheres (PDR@GNPs) were fabricated and conjugated with the SCCA monoclonal antibody as capturing substrates. Then, the hollow gold nanocages (GNCs) were adsorbed by 4-mercaptobenzoic acid (4-MBA) and further modified by the SCCA polyclonal antibody as SERS tags. Based on this sandwich immunoassay strategy, SCCA polyclonal antibody-conjugated HGNs SERS tags and SCCA monoclonal antibody-conjugated capturing substrates were used to detect SCCA antigen solutions of different concentrations. The calibration curves were established in the range from 1 × 10 −5 to 1 × 10 −10 M. The detection limit of phosphate buffer (PBS) was 7.16 pg mL −1 and that of human peripheral blood was 8.03 pg mL −1 . Finally, this novel SERS immunosensor was applied in the quantitative detection of SCCA in peripheral blood obtained from cervical intraepithelial neoplasia I (CINI), CINII, cervical cancer and healthy subjects, according to the calibration curve.Abstract : In this study, a highly specific, sensitive and reliable immunosensor has been developed for the quantitative detection of the squamous cell carcinoma antigen (SCCA) in cervical cancer, based on surface-enhanced Raman scattering (SERS). Abstract : In this study, a highly specific, sensitive and reliable immunosensor has been developed for the quantitative detection of the squamous cell carcinoma antigen (SCCA) in cervical cancer, based on surface-enhanced Raman scattering (SERS). The gold nanoparticle-coated polydopamine resin microspheres (PDR@GNPs) were fabricated and conjugated with the SCCA monoclonal antibody as capturing substrates. Then, the hollow gold nanocages (GNCs) were adsorbed by 4-mercaptobenzoic acid (4-MBA) and further modified by the SCCA polyclonal antibody as SERS tags. Based on this sandwich immunoassay strategy, SCCA polyclonal antibody-conjugated HGNs SERS tags and SCCA monoclonal antibody-conjugated capturing substrates were used to detect SCCA antigen solutions of different concentrations. The calibration curves were established in the range from 1 × 10 −5 to 1 × 10 −10 M. The detection limit of phosphate buffer (PBS) was 7.16 pg mL −1 and that of human peripheral blood was 8.03 pg mL −1 . Finally, this novel SERS immunosensor was applied in the quantitative detection of SCCA in peripheral blood obtained from cervical intraepithelial neoplasia I (CINI), CINII, cervical cancer and healthy subjects, according to the calibration curve. Enzyme-linked immunosorbent assay (ELISA) was consistent with the SERS results. The results demonstrated that the SERS immunoassay technique had potential application prospects in the early screening and diagnosis of cervical cancer. … (more)
- Is Part Of:
- Analytical methods. Volume 11:Issue 21(2019)
- Journal:
- Analytical methods
- Issue:
- Volume 11:Issue 21(2019)
- Issue Display:
- Volume 11, Issue 21 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 21
- Issue Sort Value:
- 2019-0011-0021-0000
- Page Start:
- 2809
- Page End:
- 2818
- Publication Date:
- 2019-05-21
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9ay00667b ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: