Electrocardiographic predictors of validated right ventricular outflow tract septal pacing for correct localization of transthoracic echocardiography. Issue 3 (25th March 2018)
- Record Type:
- Journal Article
- Title:
- Electrocardiographic predictors of validated right ventricular outflow tract septal pacing for correct localization of transthoracic echocardiography. Issue 3 (25th March 2018)
- Main Title:
- Electrocardiographic predictors of validated right ventricular outflow tract septal pacing for correct localization of transthoracic echocardiography
- Authors:
- Wei, Huiqiang
Tang, Jiaojiao
Chen, Dongli
Zhang, Qianhuan
Liang, Yuanhong
Liu, Lie
Wu, Shulin
Lin, Chunying
Yang, Zhiming
Chai, Chanjuan - Abstract:
- Abstract : Background: Electrocardiographic (ECG) characteristics of true right ventricular outflow tract (RVOT) septal pacing have not been clearly demonstrated. Hypothesis: We hypothesized that ECG parameters would help operators differentiate true RVOT septum from non‐septal septum. Methods: We analyzed 151 patients who underwent pacemaker implantation with a ventricular lead in the RVOT. Transthoracic echocardiographic (TTE) determination of pacing sites was applied in all patients after implantation. A 12‐lead ECG was recorded during forced ventricular pacing. Results: According to TTE orientation, pacing at the RVOT septum was achieved in 94 patients (62.3%). Compared with nonseptal pacing, septal pacing had significantly shorter QRS duration (139.2 ± 18.5 ms vs 155.5 ± 14.7 ms; P < 0.001). More frequent negative or isoelectric QRS vector in lead I (76% vs 32%; P < 0.001), lead II/III R‐wave amplitude ratio < 1 (52% vs 25%; P = 0.001), and aVR/aVL QS‐wave amplitude ratio < 1 (59% vs 32%; P = 0.001) were observed in septal pacing. Transitional zone (TZ) score (3.8 ± 0.96 vs 4.2 ± 0.90; P = 0.004) and TZ index (0.3 ± 0.5 vs 0.6 ± 0.7; P = 0.008) were significantly lower in septal pacing than in nonseptal pacing, respectively. In multivariate analysis, paced QRS duration and negative or isoelectric QRS vector in lead I independently predicted RVOT septal pacing ( P < 0.001). At ROC curve analysis, paced QRS duration ≤145 ms identified RVOT septal pacing with 85.1%Abstract : Background: Electrocardiographic (ECG) characteristics of true right ventricular outflow tract (RVOT) septal pacing have not been clearly demonstrated. Hypothesis: We hypothesized that ECG parameters would help operators differentiate true RVOT septum from non‐septal septum. Methods: We analyzed 151 patients who underwent pacemaker implantation with a ventricular lead in the RVOT. Transthoracic echocardiographic (TTE) determination of pacing sites was applied in all patients after implantation. A 12‐lead ECG was recorded during forced ventricular pacing. Results: According to TTE orientation, pacing at the RVOT septum was achieved in 94 patients (62.3%). Compared with nonseptal pacing, septal pacing had significantly shorter QRS duration (139.2 ± 18.5 ms vs 155.5 ± 14.7 ms; P < 0.001). More frequent negative or isoelectric QRS vector in lead I (76% vs 32%; P < 0.001), lead II/III R‐wave amplitude ratio < 1 (52% vs 25%; P = 0.001), and aVR/aVL QS‐wave amplitude ratio < 1 (59% vs 32%; P = 0.001) were observed in septal pacing. Transitional zone (TZ) score (3.8 ± 0.96 vs 4.2 ± 0.90; P = 0.004) and TZ index (0.3 ± 0.5 vs 0.6 ± 0.7; P = 0.008) were significantly lower in septal pacing than in nonseptal pacing, respectively. In multivariate analysis, paced QRS duration and negative or isoelectric QRS vector in lead I independently predicted RVOT septal pacing ( P < 0.001). At ROC curve analysis, paced QRS duration ≤145 ms identified RVOT septal pacing with 85.1% sensitivity and 78.9% specificity. Conclusions: This study reveals the heterogeneity of lead placement within the RVOT. Narrower paced QRS duration and negative or isoelectric QRS vector in lead I independently predict RVOT septal pacing. … (more)
- Is Part Of:
- Clinical cardiology. Volume 41:Issue 3(2018)
- Journal:
- Clinical cardiology
- Issue:
- Volume 41:Issue 3(2018)
- Issue Display:
- Volume 41, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2018-0041-0003-0000
- Page Start:
- 354
- Page End:
- 359
- Publication Date:
- 2018-03-25
- Subjects:
- Alternative Site -- Electrocardiogram -- Right Ventricular Outflow Tract -- Transthoracic Echocardiography
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.22873 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10626.xml