Treatment of in-stent restenosis with excimer laser coronary angioplasty: benefits over scoring balloon angioplasty alone. Issue 8 (November 2016)
- Record Type:
- Journal Article
- Title:
- Treatment of in-stent restenosis with excimer laser coronary angioplasty: benefits over scoring balloon angioplasty alone. Issue 8 (November 2016)
- Main Title:
- Treatment of in-stent restenosis with excimer laser coronary angioplasty: benefits over scoring balloon angioplasty alone
- Authors:
- Hirose, Shunsuke
Ashikaga, Takashi
Hatano, Yu
Yoshikawa, Shunji
Sasaoka, Taro
Maejima, Yasuhiro
Isobe, Mitsuaki - Abstract:
- Abstract Treatment of in-stent restenosis (ISR) is associated with a high incidence of recurrence. This study evaluated the clinical safety and 6-month efficacy of excimer laser coronary angioplasty (ELCA) before scoring balloon dilatation for the treatment of ISR. Twenty-three patients with ISR were included and treatment strategy of ISR was dependent on each operator. Twelve patients among those were treated with ELCA before scoring balloon dilatation (ELCA group) and 11 patients were treated with scoring balloon alone (non-ELCA group). Acute procedural results were evaluated by quantitative coronary angiography (QCA) and frequency domain optical coherence tomography (FD-OCT). Follow-up angiography was performed in all patients and the incidence of recurrent ISR and target lesion revascularization (TLR) was determined at 6 months after initial ISR treatment. Procedural success was achieved in all patients. Baseline clinical and angiographic characteristics were similar between groups. Maximum dilatation pressure of scoring balloon was significantly lower in the ELCA group than in the non-ELCA group (9.0 ± 3.1 vs. 14.9 ± 4.3 atm, p = 0.001). In follow-up angiography, the occurrence of TLR was similar between groups (16.7 vs. 45.5 %, p = 0.09), but the late luminal loss was significantly lower in the ELCA group (0.7 ± 0.6 vs. 1.3 ± 0.7 mm, p = 0.03). ELCA is a safe and feasible technique for the treatment of ISR and associated with a relatively low recurrent restenosis inAbstract Treatment of in-stent restenosis (ISR) is associated with a high incidence of recurrence. This study evaluated the clinical safety and 6-month efficacy of excimer laser coronary angioplasty (ELCA) before scoring balloon dilatation for the treatment of ISR. Twenty-three patients with ISR were included and treatment strategy of ISR was dependent on each operator. Twelve patients among those were treated with ELCA before scoring balloon dilatation (ELCA group) and 11 patients were treated with scoring balloon alone (non-ELCA group). Acute procedural results were evaluated by quantitative coronary angiography (QCA) and frequency domain optical coherence tomography (FD-OCT). Follow-up angiography was performed in all patients and the incidence of recurrent ISR and target lesion revascularization (TLR) was determined at 6 months after initial ISR treatment. Procedural success was achieved in all patients. Baseline clinical and angiographic characteristics were similar between groups. Maximum dilatation pressure of scoring balloon was significantly lower in the ELCA group than in the non-ELCA group (9.0 ± 3.1 vs. 14.9 ± 4.3 atm, p = 0.001). In follow-up angiography, the occurrence of TLR was similar between groups (16.7 vs. 45.5 %, p = 0.09), but the late luminal loss was significantly lower in the ELCA group (0.7 ± 0.6 vs. 1.3 ± 0.7 mm, p = 0.03). ELCA is a safe and feasible technique for the treatment of ISR and associated with a relatively low recurrent restenosis in comparison with scoring balloon dilatation alone. … (more)
- Is Part Of:
- Lasers in medical science. Volume 31:Issue 8(2016)
- Journal:
- Lasers in medical science
- Issue:
- Volume 31:Issue 8(2016)
- Issue Display:
- Volume 31, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2016-0031-0008-0000
- Page Start:
- 1691
- Page End:
- 1696
- Publication Date:
- 2016-11
- Subjects:
- Percutaneous coronary intervention -- Optical coherence tomography -- ELCA -- In-stent restenosis -- Scoring balloon
Lasers in medicine -- Periodicals
610.28 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://link.springer.com/journal/10103 ↗
http://www.springer.com/gb/ ↗
http://www.springer.com/gb/ ↗
http://link.springer.de/link/service/journals/10103/index.htm ↗ - DOI:
- 10.1007/s10103-016-2039-z ↗
- Languages:
- English
- ISSNs:
- 0268-8921
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.680800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10609.xml