Evaluation of mechanical strengths of three types of mini‐implants in artificial bones. Issue 2 (10th December 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of mechanical strengths of three types of mini‐implants in artificial bones. Issue 2 (10th December 2016)
- Main Title:
- Evaluation of mechanical strengths of three types of mini‐implants in artificial bones
- Authors:
- Tseng, Yu‐Chuan
Wu, Ju‐Hui
Ting, Chun‐Chan
Chen, Hong‐Sen
Chen, Chun‐Ming - Abstract:
- Abstract: We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini‐implants. Thirty mini‐implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0 × 12 mm), Type B (stainless steel, 2.0 × 12 mm), and Type C (titanium alloy, 2.0 × 11 mm). The mini‐implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT), resonance frequency (RF), and removal torque (RT)] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively) were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively). In the 45° test, the RFs of Type C (9.2 kHz) was significantly higher than those of Type A (7.0 kHz) and Type B (6.7 kHz). The anchor area of the mini‐implants was in the order of Type C (706 mm 2 ) > Type B (648 mm 2 ) > Type A (621 mm 2 ). Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT) among the three types of mini‐implants. The anchor area plays a crucial role in the mechanical strength of mini‐implants.
- Is Part Of:
- Kaohsiung journal of medical sciences. Volume 33:Issue 2(2017)
- Journal:
- Kaohsiung journal of medical sciences
- Issue:
- Volume 33:Issue 2(2017)
- Issue Display:
- Volume 33, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2017-0033-0002-0000
- Page Start:
- 96
- Page End:
- 101
- Publication Date:
- 2016-12-10
- Subjects:
- Anchor area -- Infrazygomatic mini‐implant -- Insertion torque -- Removal torque -- Resonance frequency
Medicine -- Periodicals
610.5 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.kjms-online.com/ ↗
http://www.sciencedirect.com/science/journal/1607551X?sdc=1 ↗
https://onlinelibrary.wiley.com/journal/24108650 ↗
https://www.journals.elsevier.com/the-kaohsiung-journal-of-medical-sciences ↗ - DOI:
- 10.1016/j.kjms.2016.11.001 ↗
- Languages:
- English
- ISSNs:
- 1607-551X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5085.674500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10612.xml