P09-S Searching for neurophysiological markers of VNS response predictors: PLI quantification during VNS stimulation. Issue 7 (July 2019)
- Record Type:
- Journal Article
- Title:
- P09-S Searching for neurophysiological markers of VNS response predictors: PLI quantification during VNS stimulation. Issue 7 (July 2019)
- Main Title:
- P09-S Searching for neurophysiological markers of VNS response predictors: PLI quantification during VNS stimulation
- Authors:
- Sangare, Aude
Marchi, Angela
Crepon, Benoit
Soufflet, Christine
Pruvost, Estelle
Ramdani, Celine
Chassoux, Francine
Turak, Baris
Landre, Elisabeth
Gavaret, Martine - Abstract:
- Abstract : Background: Neuronal mechanisms of Vagus nerve stimulation (VNS) efficacity in seizure control are not clearly understood. In animal models as in patients, VNS seems to produce desynchronization of interictal electroencephalography (EEG). We aim to confirm the role of EEG desynchronization as possible marker of VNS efficacity. Material and methods: We prospectively selected all EEG recordings of patients with drug resistant epilepsy treated by chronic VNS, recorded in our epileptology center from Jan 2017 to May 2018. EEG signals were acquired during a 30 min eyes-closed resting state period, using a 21 channel EEG system. Phase lag index (PLI), was used to calculate the functional connectivity strength on the first 16 artifact-free epochs for each condition (ON et OFF). Analyses were performed over a broad-filtered signal (0, 5–70 Hz) and besides overs different sub-bands filtered signals. Patients were assigned to two different groups, responders (R: reduction > 50% in seizure frequency) and non-responders (NR) Results: Eighteen patients were included. Lower synchronization values were highlighted in R patients, compared to NR, in broadband signal and in sub-bands filtered signals. These differences were significantly demonstrated for alpha ( p = 0, 03, Mann–Whitney) and beta ( p = 0, 01, Mann–Whitney) bands. Lower synchronization values were as well lower in condition ON compared to condition OFF. Conclusions: These results confirm that the beneficial effectAbstract : Background: Neuronal mechanisms of Vagus nerve stimulation (VNS) efficacity in seizure control are not clearly understood. In animal models as in patients, VNS seems to produce desynchronization of interictal electroencephalography (EEG). We aim to confirm the role of EEG desynchronization as possible marker of VNS efficacity. Material and methods: We prospectively selected all EEG recordings of patients with drug resistant epilepsy treated by chronic VNS, recorded in our epileptology center from Jan 2017 to May 2018. EEG signals were acquired during a 30 min eyes-closed resting state period, using a 21 channel EEG system. Phase lag index (PLI), was used to calculate the functional connectivity strength on the first 16 artifact-free epochs for each condition (ON et OFF). Analyses were performed over a broad-filtered signal (0, 5–70 Hz) and besides overs different sub-bands filtered signals. Patients were assigned to two different groups, responders (R: reduction > 50% in seizure frequency) and non-responders (NR) Results: Eighteen patients were included. Lower synchronization values were highlighted in R patients, compared to NR, in broadband signal and in sub-bands filtered signals. These differences were significantly demonstrated for alpha ( p = 0, 03, Mann–Whitney) and beta ( p = 0, 01, Mann–Whitney) bands. Lower synchronization values were as well lower in condition ON compared to condition OFF. Conclusions: These results confirm that the beneficial effect induced by VNS in seizure control is related to global interictal EEG desynchronization and that functional connectivity parameters could be used in clinical practice as potential predictor of VNS efficacity. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 130:Issue 7(2019:Jul.)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 130:Issue 7(2019:Jul.)
- Issue Display:
- Volume 130, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 130
- Issue:
- 7
- Issue Sort Value:
- 2019-0130-0007-0000
- Page Start:
- e97
- Page End:
- Publication Date:
- 2019-07
- Subjects:
- Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2019.04.549 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10602.xml