A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy. (May 2019)
- Record Type:
- Journal Article
- Title:
- A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy. (May 2019)
- Main Title:
- A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
- Authors:
- Arbor, Nicolas
Gasteuil, Jean
Noblet, Caroline
Moreau, Matthieu
Meyer, Philippe - Abstract:
- Highlights: Development of a GATE/Geant4 Monte Carlo toolkit for 3D superficial dose evaluation in VMAT breast cancer radiotherapy. Open source tool for clinical VMAT simulation from DICOM-RT files information (image, plan, dose and structure). Validation on PMMA phantoms by comparing EBT3 films, Treatment Planning Systems (TPS) and Monte Carlo dose calculations. Example of application on clinical VMAT treatment using patient CT. Abstract: The accuracy of superficial dose calculations for breast cancer treatments with Volumetric Modulated Arc Therapy (VMAT) is of major importance. For target volumes close to the surface, the inverse dosimetric planning can lead to very high fluences in the build-up region to properly cover the volume to be treated. Various radiotherapy modalities are currently used in parallel with additional protocols to enable a better control on the dose delivery (bolus, target volume margins). One of the difficulties currently facing medical physicists is the lack of available tools to test the impact of these different solutions on the superficial dose distribution. We present a new open source toolkit to assist medical physicists in evaluating the 3D distributions of superficial dose in VMAT breast cancer treatments. This tool is based on the GATE Monte Carlo software, a Geant4 application dedicated to medical physics. A set of macros has been developed to simulate in an easy way a full VMAT plan from the information available in the DICOM-RT filesHighlights: Development of a GATE/Geant4 Monte Carlo toolkit for 3D superficial dose evaluation in VMAT breast cancer radiotherapy. Open source tool for clinical VMAT simulation from DICOM-RT files information (image, plan, dose and structure). Validation on PMMA phantoms by comparing EBT3 films, Treatment Planning Systems (TPS) and Monte Carlo dose calculations. Example of application on clinical VMAT treatment using patient CT. Abstract: The accuracy of superficial dose calculations for breast cancer treatments with Volumetric Modulated Arc Therapy (VMAT) is of major importance. For target volumes close to the surface, the inverse dosimetric planning can lead to very high fluences in the build-up region to properly cover the volume to be treated. Various radiotherapy modalities are currently used in parallel with additional protocols to enable a better control on the dose delivery (bolus, target volume margins). One of the difficulties currently facing medical physicists is the lack of available tools to test the impact of these different solutions on the superficial dose distribution. We present a new open source toolkit to assist medical physicists in evaluating the 3D distributions of superficial dose in VMAT breast cancer treatments. This tool is based on the GATE Monte Carlo software, a Geant4 application dedicated to medical physics. A set of macros has been developed to simulate in an easy way a full VMAT plan from the information available in the DICOM-RT files (image, plan, structure and dose). The toolkit has been tested on a 6 MV Varian NovalisTx™ accelerator. The paper presents a precise comparison of 3D surface dose distributions from experimental measurements (EBT3 films), TPS (Varian Eclipse) and Monte Carlo simulation (GATE). The comparison made it possible to highlight both the TPS biases for the surface dose calculation and the good performances of the developed toolkit. The simulation of surface dose distributions on a real patient has also been performed to illustrate the potential clinical applications. … (more)
- Is Part Of:
- Physica medica. Volume 61(2019)
- Journal:
- Physica medica
- Issue:
- Volume 61(2019)
- Issue Display:
- Volume 61, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 61
- Issue:
- 2019
- Issue Sort Value:
- 2019-0061-2019-0000
- Page Start:
- 112
- Page End:
- 117
- Publication Date:
- 2019-05
- Subjects:
- Monte Carlo dosimetry -- Radiation therapy -- VMAT -- Breast cancer
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.04.012 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10604.xml