Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis. Issue 116 (July 2019)
- Record Type:
- Journal Article
- Title:
- Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis. Issue 116 (July 2019)
- Main Title:
- Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis
- Authors:
- Kolb, Manuel
Storz, Corinna
Kim, Jong Hyo
Weiss, Jakob
Afat, Saif
Nikolaou, Konstantin
Bamberg, Fabian
Othman, Ahmed E. - Abstract:
- Abstract: Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (O100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for O100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on O100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal airAbstract: Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (O100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for O100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on O100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal air (sensitivity:0.750; specificity:0.936). Regarding noise levels DN25 showed non-inferiority to O100. SNRs of O100 and DN25 showed no significant difference (p = 0.06). Conclusion: Our findings indicate that QuantaStream Denoising allows for maintained diagnostic image quality and diagnostic accuracy of low-dose abdominal CT examinations (25% of original exposition) in patients with suspected appendicitis without the need for raw sinogram data. … (more)
- Is Part Of:
- European journal of radiology. Issue 116(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 116(2019)
- Issue Display:
- Volume 116, Issue 116 (2019)
- Year:
- 2019
- Volume:
- 116
- Issue:
- 116
- Issue Sort Value:
- 2019-0116-0116-0000
- Page Start:
- 198
- Page End:
- 204
- Publication Date:
- 2019-07
- Subjects:
- CI confidence interval -- CT computed tomography -- CTDIvol CT dose index for helical CT -- DICOM digital imaging and communications in medicine -- DLP dose length product -- HU Hounsfield Units -- MRI magnetic resonance imaging -- NPV negative predictive value -- PACS picture archiving and communication system -- PPV positive predictive value -- ROI region of interest -- SD standard deviation -- SNR Signal-to-Noise Ratio
Tomography -- X-Ray computed -- Diagnostic imaging -- Appendicitis
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.04.026 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10602.xml