Description of performance degradation of photovoltaic modules using spectral mismatch correction factor under different irradiance levels. (October 2019)
- Record Type:
- Journal Article
- Title:
- Description of performance degradation of photovoltaic modules using spectral mismatch correction factor under different irradiance levels. (October 2019)
- Main Title:
- Description of performance degradation of photovoltaic modules using spectral mismatch correction factor under different irradiance levels
- Authors:
- Imai, Yurie
Chantana, Jakapan
Kawano, Yu
Hishikawa, Yoshihiro
Minemoto, Takashi - Abstract:
- Abstract: Outdoor short-circuit current (ISC ) of test photovoltaic (PV) modules, i.e., (1) multi-crystalline silicon, (2) heterostructure-with-intrinsic-thin-layer, (3) single-crystalline silicon back-contact, (4) CuInSe2, and (5) CdTe modules, was evaluated using single-crystalline silicon (sc-Si) PV module as PV module irradiance (Irr) sensor (PVMS). PVMS is used to estimate simultaneous Irr and spectral mismatch correction factor (MMPVMS ). The measured ISC (ISC-meas ) of the test PV modules at outdoor location under various conditions was corrected to the ISC under standard test condition (STC) for the corrected ISC (ISC-corrected ) using the MMPVMS and simultaneous Irr, yielding the description of the degradation of the test PV modules for the credibility of their fabrication technology. Moreover, the estimation of ISC-corrected of the test PV modules under different Irr levels was performed. The ISC-corrected with high precision, close to ISC under STC, was obtained under Irr level of ≥0.2 sun, observed by the PVMS. This leads to the increase the investigation opportunity on both sunny day and cloudy day. The ISC-corrected with the highest precision is moreover obtained under Irr level of ≥0.7 sun. The method using the simultaneous Irr and MMPVMS observed by the PVMS could be applicable under the large fluctuation of the Irr levels. Highlights: The sc-Si PV module is used as PV module irradiance (Irr) sensor (PVMS). Measured ISC of PV modules is corrected forAbstract: Outdoor short-circuit current (ISC ) of test photovoltaic (PV) modules, i.e., (1) multi-crystalline silicon, (2) heterostructure-with-intrinsic-thin-layer, (3) single-crystalline silicon back-contact, (4) CuInSe2, and (5) CdTe modules, was evaluated using single-crystalline silicon (sc-Si) PV module as PV module irradiance (Irr) sensor (PVMS). PVMS is used to estimate simultaneous Irr and spectral mismatch correction factor (MMPVMS ). The measured ISC (ISC-meas ) of the test PV modules at outdoor location under various conditions was corrected to the ISC under standard test condition (STC) for the corrected ISC (ISC-corrected ) using the MMPVMS and simultaneous Irr, yielding the description of the degradation of the test PV modules for the credibility of their fabrication technology. Moreover, the estimation of ISC-corrected of the test PV modules under different Irr levels was performed. The ISC-corrected with high precision, close to ISC under STC, was obtained under Irr level of ≥0.2 sun, observed by the PVMS. This leads to the increase the investigation opportunity on both sunny day and cloudy day. The ISC-corrected with the highest precision is moreover obtained under Irr level of ≥0.7 sun. The method using the simultaneous Irr and MMPVMS observed by the PVMS could be applicable under the large fluctuation of the Irr levels. Highlights: The sc-Si PV module is used as PV module irradiance (Irr) sensor (PVMS). Measured ISC of PV modules is corrected for ISC_corrected to standard test condition. ISC_corrected with high precision is obtained under Irr level of ≥0.2 sun. Performance degradation of PV modules can be well described. ISC_corrected with the highest precision is obtained under Irr level of ≥0.7 sun. … (more)
- Is Part Of:
- Renewable energy. Volume 141(2019)
- Journal:
- Renewable energy
- Issue:
- Volume 141(2019)
- Issue Display:
- Volume 141, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 141
- Issue:
- 2019
- Issue Sort Value:
- 2019-0141-2019-0000
- Page Start:
- 444
- Page End:
- 450
- Publication Date:
- 2019-10
- Subjects:
- Spectral mismatch correction factor -- Spectral response -- PV module irradiance sensor -- Short-circuit current -- Degradation performances -- Irradiance levels
Renewable energy sources -- Periodicals
Power resources -- Periodicals
Énergies renouvelables -- Périodiques
Ressources énergétiques -- Périodiques
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09601481 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/renewable-energy/ ↗ - DOI:
- 10.1016/j.renene.2019.04.015 ↗
- Languages:
- English
- ISSNs:
- 0960-1481
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7364.187000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: