Comparison of Modern Rigid Fixation Plating Outcomes for Segmental Mandibular Microvascular Reconstruction. (3rd October 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of Modern Rigid Fixation Plating Outcomes for Segmental Mandibular Microvascular Reconstruction. (3rd October 2018)
- Main Title:
- Comparison of Modern Rigid Fixation Plating Outcomes for Segmental Mandibular Microvascular Reconstruction
- Authors:
- McCann, Adam C.
Shnayder, Yelizaveta
Przylecki, Wojciech H.
Kakarala, Kiran
Nazir, Niaman
Girod, Douglas A.
Andrews, Brian T. - Abstract:
- Abstract : Objectives/Hypothesis: New advances in osseous microvascular mandibular rigid fixation are being employed at many institutions. These include standardized prebent/preformed reconstruction plates as well as computer‐aided design/computer‐aided manufacturing (CAD/CAM) custom plates that are patient specific. Our goal was to assess and compare the outcomes of both of these new technologies when utilized for mandibular microvascular reconstruction. Study Design: Retrospective chart review. Methods: Subjects were categorized into two groups according to their mandibular rigid fixation technique: group 1 = prebent/preformed plates and group 2 = CAD/CAM custom plates. Primary outcome measures were 1) perioperative complications (defined as deep tissue infection, wound dehiscence resulting in bone exposure, and/or plate exposure) and 2) reoperation rates for mandibular hardware failure/explantation. Statistical analysis consisted of χ 2, Fisher exact test, and multivariable regression models. Results: A total of 142 subjects underwent microvascular mandibular reconstruction in a 6‐year period. Eighty‐nine subjects utilized prebent/preformed plates, and 53 employed CAD/CAM custom plates. Perioperative complications occurred in 32 of 89 (35.9%) subjects with prebent/preformed plates and 11 of 53 (20.7%) subjects using CAD/CAM custom plates. Reoperation requiring hardware explantation occurred in 18 of 89 (20.2%) subjects and three of 53 (5.6%) using CAD/CAM custom plates.Abstract : Objectives/Hypothesis: New advances in osseous microvascular mandibular rigid fixation are being employed at many institutions. These include standardized prebent/preformed reconstruction plates as well as computer‐aided design/computer‐aided manufacturing (CAD/CAM) custom plates that are patient specific. Our goal was to assess and compare the outcomes of both of these new technologies when utilized for mandibular microvascular reconstruction. Study Design: Retrospective chart review. Methods: Subjects were categorized into two groups according to their mandibular rigid fixation technique: group 1 = prebent/preformed plates and group 2 = CAD/CAM custom plates. Primary outcome measures were 1) perioperative complications (defined as deep tissue infection, wound dehiscence resulting in bone exposure, and/or plate exposure) and 2) reoperation rates for mandibular hardware failure/explantation. Statistical analysis consisted of χ 2, Fisher exact test, and multivariable regression models. Results: A total of 142 subjects underwent microvascular mandibular reconstruction in a 6‐year period. Eighty‐nine subjects utilized prebent/preformed plates, and 53 employed CAD/CAM custom plates. Perioperative complications occurred in 32 of 89 (35.9%) subjects with prebent/preformed plates and 11 of 53 (20.7%) subjects using CAD/CAM custom plates. Reoperation requiring hardware explantation occurred in 18 of 89 (20.2%) subjects and three of 53 (5.6%) using CAD/CAM custom plates. Statistical comparison of perioperative complications between the two groups approached significance ( P = .0556), and the rate of reoperation was significant favoring CAD/CAM implants ( P = .0180). Conclusions: In our experience, CAD/CAM custom plates utilized for rigid fixation during microvascular mandibular reconstruction demonstrated fewer complications and statistically lower reoperation rates when compared with prebent/preformed plates. Level of Evidence: 2c Laryngoscope, 129:1081–1086, 2019 … (more)
- Is Part Of:
- Laryngoscope. Volume 129:Number 5(2019)
- Journal:
- Laryngoscope
- Issue:
- Volume 129:Number 5(2019)
- Issue Display:
- Volume 129, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 129
- Issue:
- 5
- Issue Sort Value:
- 2019-0129-0005-0000
- Page Start:
- 1081
- Page End:
- 1086
- Publication Date:
- 2018-10-03
- Subjects:
- Rigid fixation -- mandibular reconstruction -- computer‐aided design and computer‐aided manufacturing -- plating
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.27406 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10585.xml