Application of Six Sigma for evaluating the analytical quality of tumor marker assays. Issue 2 (2nd October 2018)
- Record Type:
- Journal Article
- Title:
- Application of Six Sigma for evaluating the analytical quality of tumor marker assays. Issue 2 (2nd October 2018)
- Main Title:
- Application of Six Sigma for evaluating the analytical quality of tumor marker assays
- Authors:
- Liu, Qian
Fu, Mei
Yang, Fumeng
Liang, Wei
Yang, Chuanxi
Zhu, Wenjun
Ma, Liming
Zhao, Changxin - Abstract:
- Abstract : Context: The results of detection assays for the same specimen are usually quite different in different laboratories or when tested with different detection systems. Objective: This study was designed to investigate the value of applying sigma metrics derived from different standards for allowable total error (TEa) in evaluating the analytical quality of tumor marker assays. Methods: Assays were evaluated for these six tumor markers: total prostate‐specific antigen (tPSA), carcinoembryonic antigen (CEA), alpha‐fetoprotein (AFP), carbohydrate antigen 199 (CA199), carbohydrate antigen 125 (CA125), and carbohydrate antigen 153 (CA153). Sigma values were calculated for two concentrations of quality control products to assess differences in quality of tumor marker assays. Improvement measures were recommended according to the quality goal index, and appropriate quality control rules were selected according to the sigma value. Results: The sigma value was highest using the higher biological variation‐derived "appropriate" TEa standard: it was sigma ≥6 or higher in 16.7% of tumor markers. Sigma was below 6 for all tumor markers using the other three TEa. CEA, AFP, CA199, CA125, and CA153 required improved precision. The marker tPSA required improve precision and accuracy. According to sigma values by using China's external quality assessment standards, CEA, AFP, CA125, and CA153 require 13s /22s /R4s /41s multirules for internal quality control, CA199 requires use of 13sAbstract : Context: The results of detection assays for the same specimen are usually quite different in different laboratories or when tested with different detection systems. Objective: This study was designed to investigate the value of applying sigma metrics derived from different standards for allowable total error (TEa) in evaluating the analytical quality of tumor marker assays. Methods: Assays were evaluated for these six tumor markers: total prostate‐specific antigen (tPSA), carcinoembryonic antigen (CEA), alpha‐fetoprotein (AFP), carbohydrate antigen 199 (CA199), carbohydrate antigen 125 (CA125), and carbohydrate antigen 153 (CA153). Sigma values were calculated for two concentrations of quality control products to assess differences in quality of tumor marker assays. Improvement measures were recommended according to the quality goal index, and appropriate quality control rules were selected according to the sigma value. Results: The sigma value was highest using the higher biological variation‐derived "appropriate" TEa standard: it was sigma ≥6 or higher in 16.7% of tumor markers. Sigma was below 6 for all tumor markers using the other three TEa. CEA, AFP, CA199, CA125, and CA153 required improved precision. The marker tPSA required improve precision and accuracy. According to sigma values by using China's external quality assessment standards, CEA, AFP, CA125, and CA153 require 13s /22s /R4s /41s multirules for internal quality control, CA199 requires use of 13s /22s /R4s /41s /8x multirules, and tPSA requires maximum quality control rules. Conclusion: Six Sigma is useful for evaluating performance of tumor markers assays and has important application value in the quality control of these assays. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 33:Issue 2(2019)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 33:Issue 2(2019)
- Issue Display:
- Volume 33, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2019-0033-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-10-02
- Subjects:
- allowable total error -- quality control rules -- sigma metrics -- tumor marker
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22682 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10575.xml