Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis. (16th November 2008)
- Record Type:
- Journal Article
- Title:
- Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis. (16th November 2008)
- Main Title:
- Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis
- Authors:
- Okumura, Miwa
Ota, Takamasa
Kainuma, Kazuhisa
Sayre, James W.
McNitt-Gray, Michael
Katada, Kazuhiro - Other Names:
- Wei Guowei Academic Editor.
- Abstract:
- Abstract : Objective . For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As reported in previous studies, edge-preserving adaptive image filters, which selectively eliminate only the noise elements that are increased when the radiation dose is reduced without affecting the sharpness of images, have been developed. In the present study, we employed receiver operating characteristic (ROC) analysis to assess the effects of the quantum denoising system (QDS), which is an edge-preserving adaptive filter that we have developed, on low-contrast resolution, and to evaluate to what degree the radiation dose can be reduced while maintaining acceptable low-contrast resolution. Materials and Methods . The low-contrast phantoms (Catphan 412) were scanned at various tube current settings, and ROC analysis was then performed for the groups of images obtained with/without the use of QDS at each tube current to determine whether or not a target could be identified. The tube current settings for which the area under the ROC curve (Az value) was approximately 0.7 were determined for both groups of images with/without the use of QDS. Then, the radiation dose reduction ratio when QDS was used was calculated by converting the determined tube current to the radiation dose. Results . The use of the QDS edge-preserving adaptive image filter allowed the radiation dose to be reduced by up to 38%. Conclusion . The QDS wasAbstract : Objective . For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As reported in previous studies, edge-preserving adaptive image filters, which selectively eliminate only the noise elements that are increased when the radiation dose is reduced without affecting the sharpness of images, have been developed. In the present study, we employed receiver operating characteristic (ROC) analysis to assess the effects of the quantum denoising system (QDS), which is an edge-preserving adaptive filter that we have developed, on low-contrast resolution, and to evaluate to what degree the radiation dose can be reduced while maintaining acceptable low-contrast resolution. Materials and Methods . The low-contrast phantoms (Catphan 412) were scanned at various tube current settings, and ROC analysis was then performed for the groups of images obtained with/without the use of QDS at each tube current to determine whether or not a target could be identified. The tube current settings for which the area under the ROC curve (Az value) was approximately 0.7 were determined for both groups of images with/without the use of QDS. Then, the radiation dose reduction ratio when QDS was used was calculated by converting the determined tube current to the radiation dose. Results . The use of the QDS edge-preserving adaptive image filter allowed the radiation dose to be reduced by up to 38%. Conclusion . The QDS was found to be useful for reducing the radiation dose without affecting the low-contrast resolution in MSCT studies. … (more)
- Is Part Of:
- International journal of biomedical imaging. Volume 2008(2008)
- Journal:
- International journal of biomedical imaging
- Issue:
- Volume 2008(2008)
- Issue Display:
- Volume 2008, Issue 2008 (2008)
- Year:
- 2008
- Volume:
- 2008
- Issue:
- 2008
- Issue Sort Value:
- 2008-2008-2008-0000
- Page Start:
- Page End:
- Publication Date:
- 2008-11-16
- Subjects:
- Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Imagerie pour le diagnostic
Imagerie médicale
Diagnostic imaging
Imaging systems in medicine
Diagnostic Imaging -- Periodicals
Electronic journals
Periodicals
616.0754 - Journal URLs:
- https://www.hindawi.com/journals/ijbm/ ↗
http://www.hindawi.com/journals/ijbi ↗
http://bibpurl.oclc.org/web/20044 ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=496&action=archive ↗ - DOI:
- 10.1155/2008/379486 ↗
- Languages:
- English
- ISSNs:
- 1687-4188
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10536.xml