A novel approach for performance improvement of liquid to vapor based battery cooling systems. (1st May 2019)
- Record Type:
- Journal Article
- Title:
- A novel approach for performance improvement of liquid to vapor based battery cooling systems. (1st May 2019)
- Main Title:
- A novel approach for performance improvement of liquid to vapor based battery cooling systems
- Authors:
- Al-Zareer, Maan
Dincer, Ibrahim
Rosen, Marc A. - Abstract:
- Highlights: Batteries arrangement effect on the cooling system performance is investigated. Boiling simulation is experimentally validated to asses cooling system performance. Various charging and discharging cycles are considered. Abstract: This paper examines the effects of varying the battery pack geometry, mainly the spacing between the batteries in the pack, when it is cooled with recently proposed liquid to vapor battery cooling systems. In these, the coolant forms a liquid pool in which the batteries in the pack are partly or completely submerged. The liquid pool is kept at a pressure for which the corresponding saturation temperature is around the lower end of the battery optimum operation temperature. When the batteries are charging or discharging they generate thermal energy and their temperature increases, and exceeds the saturation temperature of the pool. Then, the pool absorbs the generated heat and starts to evaporate. Some of the advantages of the liquid to vapor cooling system are higher latent heat, which increases the amount of heat the system can remove, and constant phase change temperature. In addition, the phase changing from liquid to vapor has the advantage of high heat transfer rate of boiling when the temperature of the surface is high enough (5 °C more than the saturation temperature). The main parameter considered in this study is the spacing between the batteries in the pack. Four different battery spacings are considered, which are essentiallyHighlights: Batteries arrangement effect on the cooling system performance is investigated. Boiling simulation is experimentally validated to asses cooling system performance. Various charging and discharging cycles are considered. Abstract: This paper examines the effects of varying the battery pack geometry, mainly the spacing between the batteries in the pack, when it is cooled with recently proposed liquid to vapor battery cooling systems. In these, the coolant forms a liquid pool in which the batteries in the pack are partly or completely submerged. The liquid pool is kept at a pressure for which the corresponding saturation temperature is around the lower end of the battery optimum operation temperature. When the batteries are charging or discharging they generate thermal energy and their temperature increases, and exceeds the saturation temperature of the pool. Then, the pool absorbs the generated heat and starts to evaporate. Some of the advantages of the liquid to vapor cooling system are higher latent heat, which increases the amount of heat the system can remove, and constant phase change temperature. In addition, the phase changing from liquid to vapor has the advantage of high heat transfer rate of boiling when the temperature of the surface is high enough (5 °C more than the saturation temperature). The main parameter considered in this study is the spacing between the batteries in the pack. Four different battery spacings are considered, which are essentially multiples of the radius of the battery, including twice the radius, equal to the radius and half of the radius. The effects on the performance of the considered parameters are measured and assessed through the thermal performance of the cooling system, which is measured by the battery maximum temperature and the maximum temperature difference across the pack and through the battery. The performance is assessed through 600 s of charging and discharging cycles for various cycle rates (4C, 5C and 6C) and for a constant amount of liquid coolant initially covering the entire height of the battery. The results show that reducing the spacing between the batteries increases the maximum temperature of the battery, but improves the thermal uniformity through the battery. Only the configuration with battery spacing equal to twice the radius, was able to maintain coolant in the liquid phase at the end of the 600 s 4C cycle. … (more)
- Is Part Of:
- Energy conversion and management. Volume 187(2019)
- Journal:
- Energy conversion and management
- Issue:
- Volume 187(2019)
- Issue Display:
- Volume 187, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 187
- Issue:
- 2019
- Issue Sort Value:
- 2019-0187-2019-0000
- Page Start:
- 191
- Page End:
- 204
- Publication Date:
- 2019-05-01
- Subjects:
- Cooling system -- Battery -- Electric vehicle -- Heat and mass transfer
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2019.02.063 ↗
- Languages:
- English