Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted immediately post-abortion: a multicenter, prospective, observational cohort study in Chinese women. (4th May 2018)
- Record Type:
- Journal Article
- Title:
- Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted immediately post-abortion: a multicenter, prospective, observational cohort study in Chinese women. (4th May 2018)
- Main Title:
- Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted immediately post-abortion: a multicenter, prospective, observational cohort study in Chinese women
- Authors:
- Chen, Xiaoning
Li, Qianxi
Wang, Xiaoye
Chen, Jing
Lv, Wen
Shi, Bin
Wang, Hong
Luo, Jianru
Li, Jian - Abstract:
- Abstract: Background: To describe the bleeding pattern (primary outcome), side effects, treatment satisfaction and 6 month continuity rates associated with the 52 mg levonorgestrel intrauterine system (LNG-IUS) and the copper intrauterine device (Cu-IUD) inserted immediately after abortion. Methods: This multicenter, prospective, observational cohort study enrolled healthy women (aged ≥18 years) inserted with LNG-IUS or Cu-IUD immediately after first-trimester surgical abortion and followed up to 6 months. Bleeding pattern was obtained through daily patient bleeding diaries. Results: From 2013 to 2014, we enrolled 512 women (LNG-IUS = 312 [median age: 32.0 years] and Cu-IUD = 200 [median age: 30.0 years]) from nine Chinese centers. LNG-IUS resulted in a significantly lower number of bleeding/spotting days in the second 90 day reference period compared with Cu-IUD (median 14.5 vs. 18.0 days, p < .0001). Amenorrhea rate (no bleeding/spotting day in the second 90 day reference period) and no menstrual bleeding rate (absence of bleeding days in the second 90 day reference period) were significantly higher in LNG-IUS compared to Cu-IUD (13.9% vs. 0% and 39.5% vs. 0%; p < .001 for all). No dysmenorrhea was higher at the last follow-up in LNG-IUS users than Cu-IUD users (81.2% vs. 76%; p = .0047). Both treatments had a high satisfaction rate among women at both the follow-up visits, and the majority of them continued with the treatment. The rates of adverse events (e.g.Abstract: Background: To describe the bleeding pattern (primary outcome), side effects, treatment satisfaction and 6 month continuity rates associated with the 52 mg levonorgestrel intrauterine system (LNG-IUS) and the copper intrauterine device (Cu-IUD) inserted immediately after abortion. Methods: This multicenter, prospective, observational cohort study enrolled healthy women (aged ≥18 years) inserted with LNG-IUS or Cu-IUD immediately after first-trimester surgical abortion and followed up to 6 months. Bleeding pattern was obtained through daily patient bleeding diaries. Results: From 2013 to 2014, we enrolled 512 women (LNG-IUS = 312 [median age: 32.0 years] and Cu-IUD = 200 [median age: 30.0 years]) from nine Chinese centers. LNG-IUS resulted in a significantly lower number of bleeding/spotting days in the second 90 day reference period compared with Cu-IUD (median 14.5 vs. 18.0 days, p < .0001). Amenorrhea rate (no bleeding/spotting day in the second 90 day reference period) and no menstrual bleeding rate (absence of bleeding days in the second 90 day reference period) were significantly higher in LNG-IUS compared to Cu-IUD (13.9% vs. 0% and 39.5% vs. 0%; p < .001 for all). No dysmenorrhea was higher at the last follow-up in LNG-IUS users than Cu-IUD users (81.2% vs. 76%; p = .0047). Both treatments had a high satisfaction rate among women at both the follow-up visits, and the majority of them continued with the treatment. The rates of adverse events (e.g. oligomenorrhea, amenorrhea) in the LNG-IUS and Cu-IUD groups were 77.2% and 44.5% ( p < .0001), respectively. Conclusion: LNG-IUS post-abortion shows better bleeding patterns, and reduced dysmenorrhea and bleeding amount, but with a similar safety profile compared with Cu-IUD. ClinicalTrials.gov identifier: NCT01958684 … (more)
- Is Part Of:
- Current medical research and opinion. Volume 34:Number 5(2018)
- Journal:
- Current medical research and opinion
- Issue:
- Volume 34:Number 5(2018)
- Issue Display:
- Volume 34, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 5
- Issue Sort Value:
- 2018-0034-0005-0000
- Page Start:
- 873
- Page End:
- 880
- Publication Date:
- 2018-05-04
- Subjects:
- Levonorgestrel-releasing intrauterine system -- bleeding patterns -- dysmenorrhea severity -- satisfaction
Clinical medicine -- Periodicals
Therapeutics -- Periodicals
615.5 - Journal URLs:
- http://informahealthcare.com ↗
- DOI:
- 10.1080/03007995.2017.1421919 ↗
- Languages:
- English
- ISSNs:
- 0300-7995
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3500.301000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10536.xml