Spatial resolution and velocity field improvement of 4D‐flow MRI. Issue 5 (24th November 2016)
- Record Type:
- Journal Article
- Title:
- Spatial resolution and velocity field improvement of 4D‐flow MRI. Issue 5 (24th November 2016)
- Main Title:
- Spatial resolution and velocity field improvement of 4D‐flow MRI
- Authors:
- Callaghan, Fraser M.
Grieve, Stuart M. - Abstract:
- Abstract : Purpose: 4D‐flow MRI obtains a time‐dependent 3D velocity field; however, its use for the calculation of higher‐order parameters is limited by noise. We present an algorithm for denoising 4D‐flow data. Theory and Methods: By integrating a velocity field and eliminating streamlines in noisy flow, depicted by high curvature, a denoised dataset may be extracted. This method, defined as the velocity field improvement (VFIT) algorithm, was validated in an analytical dataset and using in vivo data in comparison with a computation fluid dynamics (CFD) simulation. As a proof of principal, wall shear stress (WSS) measurements in the descending aorta were compared with those defined by CFD. Results: The VFIT algorithm achieved a >100% noise reduction of a corrupted analytical dataset. In addition, 4D‐flow data were cleaned to show improved spatial resolution and near wall velocity representation. WSS measures compared well with CFD data and bulk flow dynamics were retained (<2% difference in flow measurements). Conclusion: This study presents a method for denoising 4D‐flow datasets with improved spatial resolution. Bulk flow dynamics are accurately conserved while velocity and velocity gradient fields are improved; this is important in the calculation of higher‐order parameters such as WSS, which are shown to be more comparable to CFD measures. Magn Reson Med 78:1959–1968, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
- Is Part Of:
- Magnetic resonance in medicine. Volume 78:Issue 5(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 78:Issue 5(2017)
- Issue Display:
- Volume 78, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 78
- Issue:
- 5
- Issue Sort Value:
- 2017-0078-0005-0000
- Page Start:
- 1959
- Page End:
- 1968
- Publication Date:
- 2016-11-24
- Subjects:
- 4D‐flow -- denoising -- wall shear stress
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26557 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: