Estimating and eliminating the excitation errors in bipolar gradient composite excitations caused by radiofrequency‐gradient delay: Example of bipolar spokes pulses in parallel transmission. Issue 5 (26th December 2016)
- Record Type:
- Journal Article
- Title:
- Estimating and eliminating the excitation errors in bipolar gradient composite excitations caused by radiofrequency‐gradient delay: Example of bipolar spokes pulses in parallel transmission. Issue 5 (26th December 2016)
- Main Title:
- Estimating and eliminating the excitation errors in bipolar gradient composite excitations caused by radiofrequency‐gradient delay: Example of bipolar spokes pulses in parallel transmission
- Authors:
- Tse, Desmond H.Y.
Wiggins, Christopher J.
Poser, Benedikt A. - Abstract:
- Abstract : Purpose: To eliminate a slice‐position–dependent excitation error commonly observed in bipolar‐gradient composite excitations such as spokes pulses in parallel transmission. Theory and Methods: An undesired timing delay between subpulses in the composite pulse and their bipolar slice‐selective gradient is hypothesized to cause the error. A mathematical model is presented here to relate this mismatch to an induced slice‐position–dependent phase difference between the subpulses. A new navigator method is proposed to measure the timing mismatch and eliminate the error. This is demonstrated at 7 Tesla with flip‐angle maps measured by a presaturation turbo‐flash sequence and in vivo images acquired by a simultaneous multislice/echo‐planar imaging (SMS‐EPI) sequence. Results: Error‐free flip‐angle maps were obtained in two ways: 1) by correcting the time delay directly and 2) by applying the corresponding slice‐position–dependent phase differences to the subpulses. This confirms the validity of the mathematical description. The radiofrequency (RF)‐gradient delay measured by the navigator method was of 6.3 μs, which agreed well with the estimate from flip‐angle maps at different delay times. By applying the timing correction, accurately excited EPI images were acquired with bipolar dual‐spokes SMS‐2 excitations. Conclusion: An effective correction is proposed to mitigate slice‐position–dependent errors in bipolar composite excitations caused by undesired RF‐gradientAbstract : Purpose: To eliminate a slice‐position–dependent excitation error commonly observed in bipolar‐gradient composite excitations such as spokes pulses in parallel transmission. Theory and Methods: An undesired timing delay between subpulses in the composite pulse and their bipolar slice‐selective gradient is hypothesized to cause the error. A mathematical model is presented here to relate this mismatch to an induced slice‐position–dependent phase difference between the subpulses. A new navigator method is proposed to measure the timing mismatch and eliminate the error. This is demonstrated at 7 Tesla with flip‐angle maps measured by a presaturation turbo‐flash sequence and in vivo images acquired by a simultaneous multislice/echo‐planar imaging (SMS‐EPI) sequence. Results: Error‐free flip‐angle maps were obtained in two ways: 1) by correcting the time delay directly and 2) by applying the corresponding slice‐position–dependent phase differences to the subpulses. This confirms the validity of the mathematical description. The radiofrequency (RF)‐gradient delay measured by the navigator method was of 6.3 μs, which agreed well with the estimate from flip‐angle maps at different delay times. By applying the timing correction, accurately excited EPI images were acquired with bipolar dual‐spokes SMS‐2 excitations. Conclusion: An effective correction is proposed to mitigate slice‐position–dependent errors in bipolar composite excitations caused by undesired RF‐gradient timing delays. Magn Reson Med 78:1883–1890, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 78:Issue 5(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 78:Issue 5(2017)
- Issue Display:
- Volume 78, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 78
- Issue:
- 5
- Issue Sort Value:
- 2017-0078-0005-0000
- Page Start:
- 1883
- Page End:
- 1890
- Publication Date:
- 2016-12-26
- Subjects:
- ultra‐high‐field MR -- parallel transmission -- excitation errors -- bipolar gradient spokes pulses -- SMS‐pTX -- EPI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26586 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10517.xml